background image

4

We Think of Customer Satisfactio

n

Warning

◆ Damage by excessive weight can cause the unit to overheat
    and/or fire.

◆ Lack of insulation causes an electric leakage, shock and fire.

◆ Operating the product under bad conditions may cause fire
    or electric shock.

◆ An electric short or fire can occur.

◆ It may cause explosion and fire.

Do not place or store heavy items or the top
of the product.

Do not install the machine under humidity area or
near the area where water could spatter.

Stop operation
When the smell of burning or smoke is emitted
from the machine, or if the product malfunctions,
immediately unplug the product and stop operation.

Prohibition of use:
Replace or tighten the receptacle if it is loose.

Prohibition of use:
Do not use flammable gas near the icemaker.

Содержание IM-0350-AC

Страница 1: ...in any other country where the electric voltage for its power supply is not available This product is designed for indoor installation Please be sure to install it indoors The external appearance desi...

Страница 2: ...g Electrical Connection After Installation 2 Specifications 3 Part names 5 Operation Guide ICE MAKING WASH OFF Adjusting Ice Thickness 6 Operating Status Display Operating Status Display Display of Fl...

Страница 3: ...oreign material or dust etc with a clean dry towel Use a single erceptacle of r the ice machine Clean the plug Failure to follow these instructions may result in severe personal injury or death SHOULD...

Страница 4: ...an occur It may cause explosion and fire Do not place or store heavy items or the top of the product Do not install the machine under humidity area or near the area where water could spatter Stop oper...

Страница 5: ...rrent leak electric shock and or fire Be sure to contact the customer service center if the power cord or plug gets peeled or damaged Do not disassemble Do not modify the parts of icemaker and repair...

Страница 6: ...d circuit may cause product failure or an electric shock Using multiple appliances on one power strip may cause fire Thus be sure to plug only one appliance especially when using this product Disconne...

Страница 7: ...has various parts including metal sheet which may cause injury Plugging in right away may cause overload and malfunction Caution Remove any moisture oil anything that may cause slipping on the ground...

Страница 8: ...g 63 5 lb 138 9 10 After Being Packaged kg 74 5 lb 163 1 10 Compressor 0 5 HP Condenser Air Cooled Refrigerant R 404A Water Adjust Valve Setting Value Fuse PCB AC 250 V 5 A Operating temperature Tempe...

Страница 9: ...umber EA 210 280 Maximum Manufacturing Capacitor kg day 210 10 lb day 463 10 Storage Option Storage Capacity kg IB 022 22 160 IB 026 22 200 lb IB 022 22 350 IB 026 22 440 Size W X D X H mm Ice Maker 5...

Страница 10: ...0 37 x 1 14 x 0 86 Number EA 210 280 Maximum Manufacturing Capacitor kg day 240 10 lb day 530 10 Storage Option Storage Capacity kg IB 022 22 160 IB 026 22 200 lb IB 022 22 350 IB 026 22 440 Size W X...

Страница 11: ...ore Being Packaged kg 69 5 lb 152 10 After Being Packaged kg 83 5 lb 183 10 Compressor 1 2 HP Condenser Air Cooled Refrigerant R 404A Water Adjust Valve Setting Value Fuse PCB AC 250 V 5 A Operating t...

Страница 12: ...1 PH Current Consumption 9 0 A 9 0 A Weight Before Being Packaged kg 73 5 5 72 5 5 lb 162 10 160 10 After Being Packaged kg 87 5 5 86 5 5 lb 193 10 191 10 Compressor 3 4 HP 3 4 HP Condenser Air Cooled...

Страница 13: ...Consumption 11 A 11 A Weight Before Being Packaged kg 73 5 5 72 5 5 lb 162 10 160 10 After Being Packaged kg 87 5 5 86 5 5 lb 193 10 191 10 Compressor 1 HP 1 HP Condenser Air Cooled Water Cooled Refri...

Страница 14: ...n 7 0 A Weight Before Being Packaged kg 84 5 lb 185 10 After Being Packaged kg 98 5 lb 216 10 Compressor 2 HP Condenser Air Cooled Refrigerant R 404A Water Adjust Valve Setting Value Fuse PCB AC 250 V...

Страница 15: ...fore Being Packaged kg 84 5 lb 185 10 After Being Packaged kg 98 5 lb 216 10 Compressor 2 HP Condenser Air Cooled Refrigerant R 404A Water Adjust Valve Setting Value Fuse PCB AC 250 V 5 A Operating te...

Страница 16: ...V 60 1 PH Current Consumption 9 4 A 8 8 A Weight Before Being Packaged kg 105 5 98 5 lb 231 10 216 10 After Being Packaged kg 120 5 113 5 lb 265 10 249 10 Compressor 1 5 HP 1 5 HP Condenser Air Coole...

Страница 17: ...T PANEL DRAIN OUTLET WATER INLET TOP PANEL FILTER POWER CORD STATUS INDICATOR FIX SCREW TOP FIX SCREW BOTTOM MODEL Wt mm Wb mm H mm IM 0460 AC AH 22 IM 0350 AC AH 22 IM 0550 AC AH 22 22 1 562 22 560 2...

Страница 18: ...RONT PANEL LEFT PANEL RIGHT PANEL DRAIN OUTLET WATER INLET TOP PANEL POWER CORD STATUS INDICATOR FIX SCREW TOP FIX SCREW BOTTOM MODEL Wt mm Wb mm H mm IM 0460 WC WH IM 0550 WC WH 30 763 30 762 22 6 57...

Страница 19: ...e minimum distance required is 20cm 8 from the walls for normal operation Places with good ventilation Inadequate ventilation will lead to poor ice making capability Installing the product on an uneve...

Страница 20: ...ter may leak during installation or operation for diverse reasons Thus proper draining must be prepared Since there is danger of electric shock due to moisture from leak be sure to observe the followi...

Страница 21: ...Right Loosen the screw on the front side and remove the panel by pulling to the front and pushing upward a little 4 Side Panel Left Press the pin on the bottom left side of the front panel and open t...

Страница 22: ...of the support bracket with the two holes of the bin and fix it with screws 3 Bins without the two holes please see followed instruction Make a 6mm diameter hole on the 25mm from the notching part of...

Страница 23: ...compressor therein Loading part Product body 4 Move the main unit of the ice maker on the top backward little by little until the bin and the front door would open safely Align back and side 5 Fix th...

Страница 24: ...ixing Bracket Storage Bin Windbreak for some models only Place the ice maker on top of the bin and ensure it is fixed The manufacturer will not be held responsible for the accidents resulting from the...

Страница 25: ...si 1 5 f FPT NPT Ice Making Drain FPT NPT How to Connect Water Supply and Drain Installing Auxiliary Drain Hose When the water stays on the floor in the machine room in the highly humid area the hole...

Страница 26: ...gauge to the high pressure nipple of the Freezing Unit 2 Place the power switch to ICE and run the product 3 Five minutes after running check whether the gauge pressure matches the setting refer to p...

Страница 27: ...When there is no grounding terminal In case of plugging the icemaker into an power outlet without a grounding terminal connect the ground wire to the copper plate and then bury it under the ground GR...

Страница 28: ...e to the icemaker The white lead must be connected to the netural of the power source See diagram below Electrical connection must be hard wired and must meet national state and local electrical code...

Страница 29: ...ng volts Plug it into a rating outlet only Open the faucet to supply water to the icemaker Open the Front panel and then Turn on the power switch to start ice making Although the length of operation t...

Страница 30: ...ose water distributor and evaporator according to the washing procedure preset by program When you place the power switch from ICE WASH it will begin washing after making and harvest ice Wash Cycle Su...

Страница 31: ...ake thicker ice turn the adjustment screw clockwise CW If you wish to make thinner ice turn the adjustment screw counterclockwise CCW Caution Condenser may be overcooled Make adjustments carefully Ice...

Страница 32: ...for 1sec Re operates if the high pressure problem is resolved High Pressure Detection 3 Consecutive Times Er 14 Flickers for 0 3sec Air cooled type Machine stops Water cooled type Re operates every ho...

Страница 33: ...MODE button to save to move to upper item 6 Press MODE button on simple display item to display the corresponding value and press MODE button again to move to upper item 7 It will turn off automatica...

Страница 34: ...Optional 1 With hot gas run the sub motor if the preset condenser temperature is exceeded 2 Range 49 59 by 1 Pump Standby Time during Ice Making Optional 1 Stops pump for the preset time when the wate...

Страница 35: ...ise to remove the water staying inside the condenser 4 Remove water and turn the handle valve to the 12 o clock position clockwise to close and reconnect supply hose and drain hose Power Switch Coolin...

Страница 36: ...jections on both sides are released from the grooves hold the front side of the water vessel with hands pull to the front side slightly pull downward to remove in a way that the stop bumps three on th...

Страница 37: ...maker for cleaning and disinfection Caution Please use proven ice maker cleaning agent and disinfectant The cleaning agent is only available from us or our agency Please read and fully understand the...

Страница 38: ...mponents in 1 liter 3 liters for cubic type of cleaning agent water mixture and clean with soft nylon brush Remove spray bar remove silicon cap on left right separate nozzle and inserts and soak them...

Страница 39: ...approximately 30 minutes turn the switch to OFF If disinfectant solution remains inside the water vessel use the drain plug to remove disinfectant solution For Cubic Type ice maker place the drain plu...

Страница 40: ...lean and remove rust immediately with a mild detergent However when the rust has gotten really bad it must be removed with 15 nitric acid solution or commercially available stainless steel cleaner 4 R...

Страница 41: ...ator reaches exceeds 5 30 minutes after the ice making started Check cooling unit Inquire Service Center Reconnect power after resolving cooling problem Run Ice Making Delay Er11 It flickers when the...

Страница 42: ...nd 0 23 0 31 inches by adjusting the sensor screw 2 Water supply level is too low or high 2 Adjust water supply delay time 3 Water supply valve failure 3 Check normal operation 4 Strainer is blocked 4...

Страница 43: ...43 MEMO...

Страница 44: ...3240422 04 Online Internet Service http www icetro com...