preliminary
preliminary
iC-PVS
LINEAR/OFF-AXIS
BATTERY-BUFFERED ABSOLUTE POSITION HALL SENSOR
Rev A2, Page 36/51
ZGATE : Z Pulse Gating Scheme
ZGATE(1:0)
Addr. 0x06; bit 1:0
reset: 00
Code
Z Pulse Gating Scheme
00
B-gated (0.5 T)
01
AB-gated (0.25 T)
10
Z pulse disabled
11
Ungated (1 T) (requires AB_IPO
≥
4 bit)
Table 48: Z Pulse Gating Scheme
T
T/4
T/4
T/4
T/4
A
B
AB-gated
B-gated
Ungated
Z
COS+
SIN+
Figure 14: ABZ signal definition and Z pulse gating
schemes
MTD : Minimum Transition Distance
The Minimum Transition Distance (MTD) sets the mini-
mum time between two successive edges of the A and
B signals (Table 49). This can be useful to avoid errors
in the motor controller. Some controllers need a mini-
mum transition distance, mainly to be able to count the
edges correctly.
A+
B+
Transition Distance Time
Figure 15: AB transition (edge) distance time
MTD(1:0)
Addr. 0x06; bit 3:2
reset: 00
Code
Minimum Transition Distance
00
80 ns
01
1
µ
s
10
reserved
11
10
µ
s
Table 49: Minimum Transition Distance
If the actual movement of the motor causes faster
AB-signals than the MTD, the AB edges transition dis-
tance will be limited to MTD. If AB-signals are continu-
ously limited by MTD the internal AB-position increas-
ingly differs from the actual absolute position. If the
difference becomes too large, the AB-calculation will
no longer work correctly, and incorrect AB-signals will
be output, e.g. with incorrect direction of rotation.
BISS Slave Interface
General protocol description
The
BiSS
interface is an open-source serial, bidirec-
tional communications interface used for absolute posi-
tion (SCD) and configuration data transmission.
In
BiSS
mode, iC-PVS acts as a
BiSS
slave and must
be connected to a
BiSS
master for proper operation.
For a detailed description of the
BiSS
Interface, please
refer to
. The
BiSS
serial proto-
col used by iC-PVS is shown in Figure 16.
'0'
SI: SLI
CLK: MA
SO: SLO
CRC(5/15:0)
START
CDS
nERR
nWARN
nCDM
START
Frame
Idle
STOP
Cycle
Timeout
LC(5:0)
...
...
IPO(5:0)
nERR
...
...
...
PC(15/7:0)
RC(39:0)
Figure 16: BiSS protocol
Single Cycle Data (SCD)
The Single Cycle Data (SCD) generated by iC-PVS,
shown in blue in Figure 16, corresponds to the abso-