preliminary
preliminary
iC-PVS
LINEAR/OFF-AXIS
BATTERY-BUFFERED ABSOLUTE POSITION HALL SENSOR
Rev A2, Page 30/51
sage is generated. The warning threshold is specified
in
V
wrn
(Elec. Char. No. 410). If the voltage at pin
VBAT drops below this warning threshold, a warning is
generated and signalized via pin NWRN, serial commu-
nication and status register (refer to Table 15).
BAT_THR: Battery Monitor Thresholds
The thresholds of
V
err
and
V
wrn
are defined by Elec.
Char. 408 and Elec. Char. 410. They can be config-
ured by configuration parameter BAT_THR according
to Table 25.
BAT_THR(2:0)
Addr. 0x08; bit 2:0
reset: 000
Code
V
err
V
wrn
0x0
3.00
3.10
0x1
3.10
3.20
0x2
3.20
3.30
0x3
3.30
3.40
0x4
3.40
3.50
others
reserved
reserved
Note:
Nominal values. Refer to Elec. Char. 408 and 410
for variation.
Table 25: Battery Monitor Thresholds
MON_FRQ: Battery Monitor Sampling Frequency
To save power, the battery monitoring is not continu-
ously enabled. The sampling frequency can be con-
figured using parameter MON_FRQ according to table
26.
MON_FRQ(2:0)
Addr. 0x08; bit 7:5
reset: 000
Code
Sampling
Frequency
Sampling
Period
I(VBAT)
typical
0x0
0.5 Hz
2000 ms
5 nA
0x1
2 Hz
500 ms
10 nA
0x2
8 Hz
125 ms
39 nA
0x3
32 Hz
32 ms
156 nA
0x4
125 Hz
8 ms
625 nA
0x5
500 Hz
2 ms
2500 nA
0x6
2000 Hz
0.5 ms
10000 nA
0x7
4000 Hz
0.25 ms
40000 nA
Table 26: Battery Monitor Sampling Frequency
VON5: Set Typical Supply Voltage
Parameter VON5 defines the typical supply voltage
of the device. iC-PVS can operate at 3.3 V and 5.0 V
respectively. Please set the parameter to the typical
supply voltage at VDD according to Table 27. The sup-
ply switching thresholds in Elec. Char. 405 and 406
change based on the VON5 setting.
VON5
Addr. 0x0A; bit 3
reset: 0
Code
Function
0
Typical supply voltage 3.3 V
1
Typical supply voltage 5.0 V
Note:
Refer to Elec. Char. 405 and 406 for details
Table 27: Set Typical Supply Voltage