ELECTRICAL CHARACTERISTICS
Operating conditions:
VDD = 3.15...5.5 V, VBAT = 3.0...5.0 V, GND = 0 V, Tj = -40...125
°
C, fslow calibrated to 34 kHz with IBIAS, unless otherwise stated.
Item
Symbol
Parameter
Conditions
Unit
No.
Min.
Typ.
Max.
I
2
C EEPROM Interface: SCL, SDA
701 Vt()hi
Input Threshold Voltage hi
1.7
2
V
702 Vt()lo
Input Threshold Voltage lo
0.8
1.4
V
703 Vt()hys
Input Hysteresis
Vt()hys = Vt()hi - Vt()lo
75
200
500
mV
704 Vs()lo
Saturation Voltage lo
I() = 4 mA
0.05
0.4
V
705 Isc()lo
Short-Circuit Current lo
VDDS = 3.15 V, V() = VDDS
8
30
mA
706 Ipu()
Pull-Up Current
V() = 0 V...VDDS - 1 V
-1000
-300
-30
µ
A
707 fclk(SCL)
I
2
C Output Frequency at SCL
30
f
fast
/
128
70
kHz
708 tbusy()cfg Duration of Configuration Phase IBP not adjusted; without EEPROM
(SDA stuck at GND)
0.5
1
ms
EEPROM access without I
2
C read error
30
40
ms
EEPROM access with I
2
C read error
250
500
ms
Digital Inputs CLK, SI, NCS and GPIOx
801 fclk(CLK)
Permissible Clock Frequency at
CLK
SPI protocol
4
MHz
SSI protocol
4
MHz
BiSS C protocol
10
MHz
802 Vt()hi
Threshold Voltage hi
1.7
2
V
803 Vt()lo
Threshold Voltage lo
0.8
1.4
V
804 Vt()hys
Hysteresis
Vt()hys = Vt()hi - Vt()lo
100
250
500
mV
805 Ipu()
Pull-Up Current at CLK, SI, NCS V() = 0 V...VDDS - 1 V
-75
-30
-3
µ
A
806 Ipd()
Pull-Down Current at GPIOx
V() = 0 V...1 V
3
30
75
µ
A
Preset Input: PRE
901 T
pulse
(
PRE
) Permissible hi pulse length on
Pin PRE
2
µ
s
902 Vt(PRE)hi Threshold Voltage hi
1.7
2
V
903 Vt(PRE)lo Threshold Voltage lo
0.8
1.4
V
904 Vt(PRE)hys Hysteresis
Vt()hys = Vt()hi - Vt()lo
100
250
500
mV
905 Ipd(PRE)
Pull-Down Current
V() = 1 V...VDDS
8
120
300
µ
A
Digital Outputs SO and GPIOx
A01 t
out
(SO)
Adaptive Slave Timeout at SO
NTOA = 0
refer to timing Figure 4
t
init
measured as first 1.5
·
T(CLK) each frame.
2 / ffast t
init
+
4 / ffast
120 /
ffast
A02 t
out
(SO)
Fixed Slave Timeout at SO
NTOA = ’1’, (120 / ffast)
20
µ
s
A03 Vs()hi
Saturation Voltage hi
Vs()hi = VDDS - V(), I() = -1.6 mA
0.05
0.4
V
A04 Vs()lo
Saturation Voltage lo
I() = 1.6 mA
0.05
0.4
V
A05 Isc()hi
Short-Circuit Current hi
VDDS = 3.15 V, V() = GND
-15
-4
mA
A06 Isc()lo
Short-Circuit Current lo
VDDS = 3.15 V, V() = VDDS
4
15
mA
50%
± AArel
0%
100%
Figure 1: Definition of AB duty cycle ratio