Chapter 7. IBM System x3690 X5
369
IBM Midrange System Storage Implementation and Best Practices Guide, SG24-6363
This book represents a compilation of best practices for deploying and configuring IBM
Midrange System Storage servers, which include the DS4000 and DS5000 family of
products.
http://www.redbooks.ibm.com/abstracts/sg246363.html
IBM System Storage DS3000: Introduction and Implementation Guide, SG24-7065
This book introduces the IBM System Storage DS3000, providing an overview of its
design and specifications, and describing in detail how to set up, configure, and administer
it.
http://www.redbooks.ibm.com/abstracts/sg247065.html
Implementing an IBM/Cisco SAN, SG24-7545
This book consolidates critical information while discussing procedures and tasks that are
likely to be encountered on a daily basis when implementing and IBM/Cisco SAN.
http://www.redbooks.ibm.com/abstracts/sg247545.html
IBM XIV Storage System: Architecture, Implementation, and Usage, SG24-7659
This book describes the concepts, architecture, and implementation of the IBM XIV
Storage System.
http://www.redbooks.ibm.com/abstracts/sg247659.html
IBM Midrange System Storage Hardware Guide, SG24-7676
This book consolidates, in one document, detailed descriptions of the hardware
configurations and options that are offered as part of the IBM Midrange System Storage
servers, which include the IBM System Storage DS4000 and DS5000 families of products.
http://www.redbooks.ibm.com/abstracts/sg247676.html
7.10 Failure detection and recovery
A memory-expanded System x3690 X5 connects to the MAX5 via a QPI connection.
Therefore, a problem with the MAX5 is equivalent to a problem with the system itself. System
alerts and reporting on the x3690 X5 will respond to failures on the MAX5.
7.10.1 System alerts
On the system hardware level, use the System x3690 X5 alerting method to analyze failure
on the MAX5. Use the following tools:
Light path diagnostics (LPD)
Light path diagnostics is a system of LEDs on the various external and internal
components of the server. When an error occurs, LEDs are lit throughout the server. By
viewing the LEDs in a particular order, you can identify the source of the error.
Integrated Management Module (IMM)
The System x3690 X5 IMM informs you of the current system status at the System Status
panel, as shown in Figure 7-62 on page 370. Use IMM to investigate server conditions
when an error or abnormal status is observed.
Содержание x3850 X5
Страница 2: ......
Страница 3: ...International Technical Support Organization IBM eX5 Implementation Guide May 2011 SG24 7909 00...
Страница 20: ...xviii IBM eX5 Implementation Guide...
Страница 32: ...12 IBM eX5 Implementation Guide...
Страница 34: ...14 IBM eX5 Implementation Guide...
Страница 74: ...54 IBM eX5 Implementation Guide...
Страница 136: ...116 IBM eX5 Implementation Guide...
Страница 238: ...218 IBM eX5 Implementation Guide...
Страница 392: ...372 IBM eX5 Implementation Guide...
Страница 466: ...446 IBM eX5 Implementation Guide...
Страница 484: ...464 IBM eX5 Implementation Guide Figure 9 14 IMM Remote Control Video Viewer showing power control options...
Страница 560: ...540 IBM eX5 Implementation Guide...
Страница 564: ...544 IBM eX5 Implementation Guide...
Страница 578: ...IBM eX5 Implementation Guide IBM eX5 Implementation Guide...
Страница 579: ......