Using the CPU Enclosure
2-7
Reading the Operator Panel Display
Attention: If you have a flashing 888 in the Operator Panel Display, do not push the
Reset/Scroll button before you carefully read the related documentation.
The operator panel display has two 16-position rows.
The operator panel display is used for:
•
Event indications and problem reporting during Power-On-Self-Test (POST) and
Configuration Methods.
•
Progress and command indications when loading diagnostics.
•
Event indications during diagnostics when a Console-Display is not available.
•
Problem reporting during diagnostics when a Console-Display is not available.
•
Check stop indications when the machine cannot recover from a check stop.
•
Crash reporting when the machine cannot recover from a crash.
•
Dump progress and command indications during dump.
•
Problem reporting when there is a power problem.
During POST, the numbers that are displayed indicate the progress of the testing. If an error
is detected that requires attention, the system unit stops, and a flashing 888 is displayed in
the operator panel display to identify the error. If this occurs, refer to the
AIX Version 4
Problem Solving Guide and Reference manual.
When the self-tests and configuration methods complete without error, the operator panel
display is blank.
Operator Panel Display
Operator Panel
Содержание ThinkPad R30
Страница 1: ...7015 Models R30 R40 and R50 CPU Enclosure Operator Guide...
Страница 12: ...xii Operator Guide...
Страница 16: ...xvi Operator Guide...
Страница 20: ...1 4 Operator Guide...
Страница 132: ...4 10 Operator Guide AC Rack Cables and the CPU Enclosure Connectors CPU Enclosure...
Страница 156: ...6 4...
Страница 194: ...10 4 Operator Guide...
Страница 238: ...B 8 Operator Guide...
Страница 248: ...D 4 Operator Guide...