Using the AC Rack
5-5
Manually Powering On the AC Rack with a PDB
Note: Ensure that the key mode switch is set to the Service position to prevent system unit
power from being switched on unexpectedly.
1. Set the key mode switch to the Service position.
Key Mode Switch
Normal
Secure
Service
Operator Panel
Power Button
Note: For a translation of this notice, see the
System Unit Safety Information manual.
CAUTION:
This product is equipped with a 3-wire power cable and plug for the user’s safety. Use
this power cable in conjunction with a properly grounded electrical outlet to avoid
electrical shock.
Notes:
Ensure that the power button is in the off position (button in the out position) before
plugging the PDB power cord into the electrical outlet.
If two PDBs are installed in the rack, plug the power cords of both PDBs into the
electrical outlets.
2. Plug the power cord for the power distribution bus into the electrical outlet.
Power
Distribution
Bus
Power Cord
Plug
Rear View of Rack