Using SystemGuard
3-31
Modify/Display Test List
Once the test list is built, you can use this option to view or modify it. Each test is identified
by a number
xxyy, where xx is the group number and yy is the test number.
1. Enter
2
in the OFF-LINE TESTS menu to view or modify the test list. The following menu
is displayed:
MODIFY/DISPLAY TEST LIST
TEST LIST (xxyy: xx = GROUP NUMBER yy = TEST NUMBER):
0101–0102–0103–0104–0105–0106–0107–0108–0109–0110–0111–0112–0150–
0151–0152
COMMANDS: xxyy> SELECT TEST
SELECT [x:exit]:
2. Select the test to be displayed or modified. For example, enter
0302
to select test 2 from
group 3.
3. When a test is selected for modification, the following screen enables you to:
– Display test parameters (both default and current values).
– Modify parameter values (reserved for service people only).
– Delete tests from the list.
TEST: 0101 (01/01) – GROUP 01 BUMP QUICK IO
– TEST 01 DEBUG LINE
PARAMETER[1] = Sub test selection
DEFAULT VALUE = 0x00000000 – PRESENT VALUE =
0x00000000
PARAMETER[2] = Processor number
DEFAULT VALUE = 0x00000008 – PRESENT VALUE =
0x00000008
PARAMETER[3] = Part ID
DEFAULT VALUE = 0xffffffff – PRESENT VALUE =
0xffffffff
COMMANDS: (+: forward test –: backward test)
Pn> CHANGE PARAMETER
D > DELETE TEST
SELECT [x:exit]:
4. The following commands are available:
P
n value [/ Pn value...] This command is reserved for customer service representatives.
D
Deletes the selected test.
+
Scrolls forward in the test parameter list.
–
Scrolls backward in the test parameter list.
x
Exits this menu and returns to the previous menu.
Содержание ThinkPad R30
Страница 1: ...7015 Models R30 R40 and R50 CPU Enclosure Operator Guide...
Страница 12: ...xii Operator Guide...
Страница 16: ...xvi Operator Guide...
Страница 20: ...1 4 Operator Guide...
Страница 132: ...4 10 Operator Guide AC Rack Cables and the CPU Enclosure Connectors CPU Enclosure...
Страница 156: ...6 4...
Страница 194: ...10 4 Operator Guide...
Страница 238: ...B 8 Operator Guide...
Страница 248: ...D 4 Operator Guide...