Table 7. Port, application, and encryption blade LED descriptions (continued)
LED purpose
Color
Status
Recommended action
Blade status LED
No light (LED is off)
Blade is either healthy or does
not have power.
Verify that the power LED is
on.
Steady amber
Blade is faulty.
Ensure blade is firmly seated
and check status by entering
the
slotShow
command. If LED
remains amber, contact IBM.
Slow-flashing amber (on 2
seconds, then off 2 seconds)
Blade is not seated correctly or
is faulty.
Pull blade out and reseat it. If
the LED continues to flash,
replace the blade.
Fast-flashing amber (on 1/2
second, then off 1/2 second)
Environmental range exceeded. Check for out-of-bounds
environmental condition and
correct it.
FC port status
No light (LED is off)
Port has no incoming power,
or there is no light or signal
carrier detected.
Verify that the power LED is
on, check the transceiver and
cable.
Polling is in progress.
Allow 60 seconds for polling to
complete.
Connected device is configured
in an offline state.
Verify the status of the
connected device.
Steady green
Port is online (connected to an
external device) but has no
traffic.
No action required.
Slow-flashing green (on 1
second, then off 1 second)
Port is online but segmented,
indicating a loopback plug or
cable or an incompatible
switch.
Verify that the correct device is
attached to the SAN768B-2.
Fast-flashing green (on 1/4
second, then off 1/4 second
Port is in internal loopback
(diagnostic).
No action required.
Flickering green
Port is online, with traffic
flowing through port.
No action required.
Steady amber
Port is receiving light or signal
carrier, but it is not online yet.
Reset the port from the
workstation using the
portEnable
or
portCfgPersistentEnable
command.
Slow-flashing amber (on 2
seconds, then off 2 seconds)
Port is disabled due to
diagnostic tests or
portDisable
or
portCfgPersistentEnable
command.
Reset the port from the
workstation using the
portEnable
or
portCfgPersistentEnable
command.
Fast-flashing amber (on 1/2
second, then off 1/2 second)
Transceiver or port is faulty.
Change the transceiver or reset
the switch from the
workstation.
Alternating green/amber
Port is bypassed
Reset port from workstation
using the
portEnable
or
portCfgPersistentEnable
command.
Chapter 4. Monitoring system components
69
Содержание SAN768B-2
Страница 2: ......
Страница 8: ...vi SAN768B 2 Installation Service and User Guide...
Страница 10: ...viii SAN768B 2 Installation Service and User Guide...
Страница 14: ...xii SAN768B 2 Installation Service and User Guide...
Страница 28: ...xxvi SAN768B 2 Installation Service and User Guide...
Страница 40: ...12 SAN768B 2 Installation Service and User Guide...
Страница 108: ...80 SAN768B 2 Installation Service and User Guide...
Страница 182: ...154 SAN768B 2 Installation Service and User Guide...
Страница 186: ...158 SAN768B 2 Installation Service and User Guide...
Страница 196: ...168 SAN768B 2 Installation Service and User Guide...
Страница 202: ...174 SAN768B 2 Installation Service and User Guide...
Страница 220: ...192 SAN768B 2 Installation Service and User Guide...
Страница 226: ...198 SAN768B 2 Installation Service and User Guide...
Страница 227: ......
Страница 228: ...Part Number 00MA746 Printed in USA GA32 0893 06 1P P N 00MA746...