Items required
v
ESD (electrostatic discharge) grounding strap
v
Workstation computer
v
Encryption blade
v
Phillips screwdriver
v
Transceivers (as needed)
v
Optical cables (as needed)
Procedures
Follow the links in the steps below to complete this installation.
1.
Verify that the blade is the correct part.
2.
Verify which slot to install the blade. Port, application, and encryption blades
can be installed in any slot 1-4 and 9-12. Up to four FS8-18 encryption blades
can be installed in a single chassis.
3.
We recommend having the latest firmware version on the CP blade. The
firmware version should match on both the active and the backup CP blades.
If the firmware is not at the latest level, obtain new code from the code
download website, and install it prior to installing the port blade. See “Fabric
OS firmware updates” on page 50 for instructions. Also refer to “Removing
and installing a CP8 control processor blade” on page 88 for details on
firmware updates.
Note:
Firmware downloads require that Ethernet connections be made to both
CP blades. Procedures for downloading and installing firmware are described
in the
Fabric OS Administrator's Guide
.
4.
Remove the filler panel or port blade. Refer to “Removing a port or
application blade” on page 84 or “Removing a filler panel” on page 87.
Attention:
A filler panel should be removed only when being replaced with
a blade or new filler panel. Any slot that is not occupied by a blade should be
occupied by a filler panel to ensure correct cooling of the chassis and
protection from dust.
5.
Install the encryption blade (“Installing a port or application blade” on page
86). Remove the protective strip from the blade contacts (if any) before
installing the blade.
6.
Repeat steps 1-5 for additional blades, if any.
7.
Install the transceivers (“Removing and installing transceivers” on page 108),
and confirm the proper operation of the blade.
8.
Install, group, and route the cables. See “Managing cables” on page 46 for
additional cabling instructions.
Attention:
Do not route cables in front of the exhaust vent, which is located
at the top on the port side of the chassis.
9.
Verify the installation. For information about how to check the status of
hardware components using the CLI, see the
Fabric OS Administrator's Guide
,
which is located on the product documentation CD.
10.
The FS8-18 encryption blade requires additional configuration to enable
encryption. See “Configuring for encryption (optional)” on page 49 for an
overview of those steps. Refer to the
Fabric OS Encryption Administrator’s Guide
Supporting Tivoli Key Lifecycle Manager (TKLM) Environments
for more detailed
information regarding encryption and TKLM key management.
142
SAN768B-2 Installation, Service, and User Guide
Содержание SAN768B-2
Страница 2: ......
Страница 8: ...vi SAN768B 2 Installation Service and User Guide...
Страница 10: ...viii SAN768B 2 Installation Service and User Guide...
Страница 14: ...xii SAN768B 2 Installation Service and User Guide...
Страница 28: ...xxvi SAN768B 2 Installation Service and User Guide...
Страница 40: ...12 SAN768B 2 Installation Service and User Guide...
Страница 108: ...80 SAN768B 2 Installation Service and User Guide...
Страница 182: ...154 SAN768B 2 Installation Service and User Guide...
Страница 186: ...158 SAN768B 2 Installation Service and User Guide...
Страница 196: ...168 SAN768B 2 Installation Service and User Guide...
Страница 202: ...174 SAN768B 2 Installation Service and User Guide...
Страница 220: ...192 SAN768B 2 Installation Service and User Guide...
Страница 226: ...198 SAN768B 2 Installation Service and User Guide...
Страница 227: ......
Страница 228: ...Part Number 00MA746 Printed in USA GA32 0893 06 1P P N 00MA746...