Table
3-1 (Page 16 of 26). Firmware Error Codes.
Error Code
Description
Action / Possible Failing FRU
2BA00327
Service Processor reports PCI Expan-
sion Card 5V Under Voltage Alert.
1. Replace Power Supply.
2. Replace I/O Board. (See notes on
3-1.)
2BA00328
Service Processor reports PCI Expan-
sion Card 3.3V Over Voltage Alert.
1. Replace Power Supply.
2. Replace I/O Board. (See notes on
3-1.)
2BA00329
Service Processor reports PCI Expan-
sion Card 3.3V Under Voltage Alert.
1. Replace Power Supply.
2. Replace I/O Board. (See notes on
3-1.)
2BA00330
Service Processor reports PCI Expan-
sion Card +12V Over Voltage Alert.
1. Replace Power Supply.
2. Replace I/O Board. (See notes on
3-1.)
2BA00331
Service Processor reports PCI Expan-
sion Card +12V Under Voltage Alert.
1. Replace Power Supply.
2. Replace I/O Board. (See notes on
3-1.)
2BA00332
Service Processor reports PCI Expan-
sion Card -12V Over Voltage Alert.
1. Replace Power Supply.
2. Replace I/O Board. (See notes on
3-1.)
2BA00333
Service Processor reports PCI Expan-
sion Card -12V Under Voltage Alert.
1. Replace Power Supply.
2. Replace I/O Board. (See notes on
3-1.)
2BA00334
Service Processor reports Generic
Slow Shutdown request.
1. Replace Power Supply.
2. Replace I/O Board. (See notes on
3-1.)
2BA00335
Service Processor reports CPU Critical
Over Temperature Slow Shutdown
request.
1. Check for cool air flow obstructions
to the system.
2. Check fans for obstructions that
prevent them from normal opera-
tion (example: a cable caught in
the fan preventing it from spinning).
3. If problem persists, replace CPU
Card.
2BA00336
Service Processor reports IO Critical
Over Temperature Slow Shutdown
request.
1. Check for cool air flow obstructions
to the system.
2. Check fans for obstructions that
prevent them from normal opera-
tion (example: a cable caught in
the fan preventing it from spinning).
3. If problem persists, replace I/O
Board. (See notes on 3-1.)
Chapter 3. Error Code to FRU Index
3-17
Содержание RS/6000 H50
Страница 1: ...RS 6000 Enterprise Server Model H50 IBM Installation and Service Guide SA38 0547 00...
Страница 16: ...xvi RS 6000 Enterprise Server Model H50 Installation and Service Guide...
Страница 30: ...1 12 RS 6000 Enterprise Server Model H50 Installation and Service Guide...
Страница 130: ...AIX and Physical Location Code Reference Table 3 50 RS 6000 Enterprise Server Model H50 Installation and Service Guide...
Страница 131: ...Chapter 3 Error Code to FRU Index 3 51...
Страница 160: ...5 18 RS 6000 Enterprise Server Model H50 Installation and Service Guide...
Страница 245: ...Chapter 8 Parts Information Chapter 8 Parts Information 8 1...
Страница 290: ...B 4 RS 6000 Enterprise Server Model H50 Installation and Service Guide...
Страница 305: ...expect 8 r or 7 r or 6 r or 4 r or 3 r delay 2 done Appendix C Modem Configurations C 15...
Страница 312: ...C 22 RS 6000 Enterprise Server Model H50 Installation and Service Guide...
Страница 316: ...D 4 RS 6000 Enterprise Server Model H50 Installation and Service Guide...
Страница 324: ...X 8 RS 6000 Enterprise Server Model H50 Installation and Service Guide...
Страница 326: ...X 10 RS 6000 Enterprise Server Model H50 Installation and Service Guide...