Specifications
The mechanical packaging, cooling, power supply, and environmental requirements
for the server is shown in the following:
Dimensions
Height
Width
Depth
350 mm
443 mm
844 mm
13.8 in.
8 (EIA units)
17.4 in.
33.2 in.
Weight
Empty
Maximum Configuration
71 kg
89 kg
157 lbs.
195 lbs.
Electrical
Power source loading typical in kVA
Power source loading maximum in kVA
Voltage range (V ac)
Frequency (hertz)
Thermal output (typical)
Thermal output (maximum)
Power requirements (typical)
Power requirements (maximum)
Power factor
Inrush current
Maximum altitude
0.52
0.56
200 to 240 (autoranging)
50 or 60
975 BTU/hr
2460 BTU/hr
285 watts
600 watts
0.8 - 0.96
50 amps
2135m (7000 ft.)
Temperature Requirements
Operating
10 to 40°C
(50 to 104°F)
Non-Operating
(Shipping)
(Ambient)
1 to 52°C
10 to 43°C
(34 to 125°F) (50 to 110°F)
Humidity Requirements
(Noncondensing)
Wet Bulb
Operating
8% to 80%
23°C (73°F)
Non-Operating
8% to 80%
27°C (80°F)
Noise Emissions
L
WAd
L
pAm
<L
pA
>
m
Impulsive or prominent
discrete tones
Operating
6.0 bels
NA
43 dBA
No
Idle
5.9 bels
N/A
40 dBA
No
Clearances
Front
Back
Left
Right
Service
1650 mm(65 in)
1015 mm(40 in)
915 mm (36 in)
915 mm (36 in)
Install/Air
Flow
Maintenance of a proper service clearance will allow proper air flow.
1-8
RS/6000 Enterprise Server Model H50 Installation and Service Guide
Содержание RS/6000 H50
Страница 1: ...RS 6000 Enterprise Server Model H50 IBM Installation and Service Guide SA38 0547 00...
Страница 16: ...xvi RS 6000 Enterprise Server Model H50 Installation and Service Guide...
Страница 30: ...1 12 RS 6000 Enterprise Server Model H50 Installation and Service Guide...
Страница 130: ...AIX and Physical Location Code Reference Table 3 50 RS 6000 Enterprise Server Model H50 Installation and Service Guide...
Страница 131: ...Chapter 3 Error Code to FRU Index 3 51...
Страница 160: ...5 18 RS 6000 Enterprise Server Model H50 Installation and Service Guide...
Страница 245: ...Chapter 8 Parts Information Chapter 8 Parts Information 8 1...
Страница 290: ...B 4 RS 6000 Enterprise Server Model H50 Installation and Service Guide...
Страница 305: ...expect 8 r or 7 r or 6 r or 4 r or 3 r delay 2 done Appendix C Modem Configurations C 15...
Страница 312: ...C 22 RS 6000 Enterprise Server Model H50 Installation and Service Guide...
Страница 316: ...D 4 RS 6000 Enterprise Server Model H50 Installation and Service Guide...
Страница 324: ...X 8 RS 6000 Enterprise Server Model H50 Installation and Service Guide...
Страница 326: ...X 10 RS 6000 Enterprise Server Model H50 Installation and Service Guide...