Table
3-1 (Page 7 of 26). Firmware Error Codes.
Error Code
Description
Action / Possible Failing FRU
2501000A
Flash write protected.
1. Turn off, turn on system unit, retry.
2. Replace I/O board. (See notes on
3-1.)
25A0xxx0
L2 Cache controller problem.
1. Replace the CPU card.
2. Replace the System board.
See error code 2B2xxx22 for xxx defi-
nitions.
25A0xxx1
L2 Cache controller problem.
1. Replace the CPU card.
2. Replace the System board.
See error code 2B2xxx22 for xxx defi-
nitions.
25A1xxx1
L2 SRAM failure
Replace the CPU card.
See error code 2B2xxx22 for xxx defi-
nitions.
25A80000
Initialization failed, device test failed.
Refer to Action under error code
25A80xxx.
25A80001
Init-nvram invoked, ALL of NVRAM ini-
tialized.
Refer to Action under error code
25A80xxx.
25A80002
Init-nvram invoked, some data parti-
tions may have been preserved.
Refer to Action under error code
25A80xxx.
25A80011
Data corruption detected, ALL of
NVRAM initialized.
Refer to Action under error code
25A80xxx.
25A80012
Data corruption detected, some data
partitions may have been preserved.
Refer to Action under error code
25A80xxx.
25A80100
NVRAM data validation check failed.
Turn off, turn on system unit and retry
the operation before replacing any
system component. Refer to Action
under error code 25A80xxx.
25A80201
Unable to expand target partition while
saving configuration variable.
Refer to Action under error code
25A80xxx.
25A80202
Unable to expand target partition while
writing error log entry.
Refer to Action under error code
25A80xxx.
25A80203
Unable to expand target partition while
writing VPD data.
Refer to Action under error code
25A80xxx.
25A80210
Setenv/$Setenv parameter error - name
contains a null character.
Refer to Action under error code
25A80xxx.
25A80211
Setenv/$Setenv parameter error - value
contains a null character.
Refer to Action under error code
25A80xxx.
3-8
RS/6000 Enterprise Server Model H50 Installation and Service Guide
Содержание RS/6000 H50
Страница 1: ...RS 6000 Enterprise Server Model H50 IBM Installation and Service Guide SA38 0547 00...
Страница 16: ...xvi RS 6000 Enterprise Server Model H50 Installation and Service Guide...
Страница 30: ...1 12 RS 6000 Enterprise Server Model H50 Installation and Service Guide...
Страница 130: ...AIX and Physical Location Code Reference Table 3 50 RS 6000 Enterprise Server Model H50 Installation and Service Guide...
Страница 131: ...Chapter 3 Error Code to FRU Index 3 51...
Страница 160: ...5 18 RS 6000 Enterprise Server Model H50 Installation and Service Guide...
Страница 245: ...Chapter 8 Parts Information Chapter 8 Parts Information 8 1...
Страница 290: ...B 4 RS 6000 Enterprise Server Model H50 Installation and Service Guide...
Страница 305: ...expect 8 r or 7 r or 6 r or 4 r or 3 r delay 2 done Appendix C Modem Configurations C 15...
Страница 312: ...C 22 RS 6000 Enterprise Server Model H50 Installation and Service Guide...
Страница 316: ...D 4 RS 6000 Enterprise Server Model H50 Installation and Service Guide...
Страница 324: ...X 8 RS 6000 Enterprise Server Model H50 Installation and Service Guide...
Страница 326: ...X 10 RS 6000 Enterprise Server Model H50 Installation and Service Guide...