Table
3-1 (Page 20 of 26). Firmware Error Codes.
Error Code
Description
Action / Possible Failing FRU
2BA00375
Service Processor reports Power
Supply #2 and DASD Fans failed.
1. Replace Power Supply #2 and
Failing DASD Fans.
2. Replace I/O Board (See notes on
3-1.)
2BA00376
Service Processor reports Power
Supply failure.
1. Replace Failing Power Supply.
2. Replace I/O Board (See notes on
3-1.)
2BA00399
Service Processor reports Unsupported
value in EPOW.
Replace I/O Board. (See notes on
3-1.)
40100005
A loss of system power detected.
Possible main power loss. If not,
replace power supply.
40100007
Immediate shutdown.
Possible main power loss. If not,
replace power supply.
40110001
Power Supply fail.
1. Power supply.
2. I/O board. (See notes on 3-1.)
3. Service processor.
40110002
Voltage is present, but not detected on
both processor cards.
1. Check cable between CPU card
and PDB for proper seating.
2. Replace power supply.
3. Replace PDB.
40110003
Voltage is present, but not detected on
one processor card. (If the system is
running, refer to the AIX error log to
find out which processor card is failing.
If the system is not running, refer to the
SP error log.)
1. Check cable between CPU card
and PDB for proper seating.
2. Replace CPU card.
3. Replace cable between CPU card
and PDB.
4. Replace PDB.
40110004
Loss of redundant power supply. (If
the system is running, refer to the AIX
error log to find out which processor
card is failing. If the system is not
running, refer to the SP error log.)
1. Power supply.
2. PDB.
3. I/O board. (See notes on 3-1.)
40110005
Loss of redundant power supply and a
DASD fan. (Refer to the SP error log
to determine which fan and power
supply is failing.)
1. Power supply.
2. DASD fan.
40111002
An unknown power problem detected.
1. Power supply.
2. I/O board. (See notes on 3-1.)
3. Service processor.
40111022
A high 5.0 voltage reading detected.
1. Power supply.
2. CPU card.
40111032
A high 3.3 voltage reading detected.
1. CPU card.
2. Power supply.
40111042
A high 2.5 voltage reading detected.
1. CPU card.
2. Power supply.
Chapter 3. Error Code to FRU Index
3-21
Содержание RS/6000 H50
Страница 1: ...RS 6000 Enterprise Server Model H50 IBM Installation and Service Guide SA38 0547 00...
Страница 16: ...xvi RS 6000 Enterprise Server Model H50 Installation and Service Guide...
Страница 30: ...1 12 RS 6000 Enterprise Server Model H50 Installation and Service Guide...
Страница 130: ...AIX and Physical Location Code Reference Table 3 50 RS 6000 Enterprise Server Model H50 Installation and Service Guide...
Страница 131: ...Chapter 3 Error Code to FRU Index 3 51...
Страница 160: ...5 18 RS 6000 Enterprise Server Model H50 Installation and Service Guide...
Страница 245: ...Chapter 8 Parts Information Chapter 8 Parts Information 8 1...
Страница 290: ...B 4 RS 6000 Enterprise Server Model H50 Installation and Service Guide...
Страница 305: ...expect 8 r or 7 r or 6 r or 4 r or 3 r delay 2 done Appendix C Modem Configurations C 15...
Страница 312: ...C 22 RS 6000 Enterprise Server Model H50 Installation and Service Guide...
Страница 316: ...D 4 RS 6000 Enterprise Server Model H50 Installation and Service Guide...
Страница 324: ...X 8 RS 6000 Enterprise Server Model H50 Installation and Service Guide...
Страница 326: ...X 10 RS 6000 Enterprise Server Model H50 Installation and Service Guide...