2. Read carefully the “Action” you must perform for the problem.
Do not exchange
FRUs unless you are instructed to do so.
3. Normally exchange only one FRU at a time, starting from the top of the FRU list
for that SRN. Always use instructions given in the page reference when
exchanging FRUs. After each FRU is exchanged, go to "MAP 410: Repair
Checkout" in
Diagnostic Information for Multiple Bus Systems to verify the repair.
Software and Microcode Errors
Some SRNs indicate that a problem might have been caused by a software error or
by a microcode error. If you have one of these SRNs, perform the following actions:
1. Make a note of the contents of the error log for the device that has the problem.
2. Go to the using-system service aids and select Display Vital Product Data to
display the VPD of the failing system. Make a note of the VPD for all the SSA
adapters and disk drive modules.
3. Report the problem to your support center. The center can tell you whether you
have a known problem and can, if necessary, provide you with a correction for
the software or microcode.
FRU Names Used in the SRN Table
This section provides a glossary of the FRU names used.
FRU Name in Table
Definition
Backplane assembly
The disk drive modules, blank disk drive modules, and
internal SSA cables, are connected to the backplane
assembly.
Disk drive module
A disk drive assembly to a carrier that plugs into the
backplane in the system unit.
Blank Disk drive module
This module must be installed in a slot that does not
contain a disk drive module. This completes the SSA
loop through the system unit.
External SSA cable
A cable that connects the bulkhead to the SSA adapter
or to an SSA subsystem.
Internal SSA cable
Attaches the backplane to the SSA adapter card.
SSA adapter card
The SSA adapter card, which is located in the using
system.
5-2
RS/6000 Enterprise Server Model H50 Installation and Service Guide
Содержание RS/6000 H50
Страница 1: ...RS 6000 Enterprise Server Model H50 IBM Installation and Service Guide SA38 0547 00...
Страница 16: ...xvi RS 6000 Enterprise Server Model H50 Installation and Service Guide...
Страница 30: ...1 12 RS 6000 Enterprise Server Model H50 Installation and Service Guide...
Страница 130: ...AIX and Physical Location Code Reference Table 3 50 RS 6000 Enterprise Server Model H50 Installation and Service Guide...
Страница 131: ...Chapter 3 Error Code to FRU Index 3 51...
Страница 160: ...5 18 RS 6000 Enterprise Server Model H50 Installation and Service Guide...
Страница 245: ...Chapter 8 Parts Information Chapter 8 Parts Information 8 1...
Страница 290: ...B 4 RS 6000 Enterprise Server Model H50 Installation and Service Guide...
Страница 305: ...expect 8 r or 7 r or 6 r or 4 r or 3 r delay 2 done Appendix C Modem Configurations C 15...
Страница 312: ...C 22 RS 6000 Enterprise Server Model H50 Installation and Service Guide...
Страница 316: ...D 4 RS 6000 Enterprise Server Model H50 Installation and Service Guide...
Страница 324: ...X 8 RS 6000 Enterprise Server Model H50 Installation and Service Guide...
Страница 326: ...X 10 RS 6000 Enterprise Server Model H50 Installation and Service Guide...