2. Call your server again.
3. At the Service Processor Main Menu, select Call-In/Call-Out Setup menu, then
select Call-Out test. This causes a simulated error condition for the purposes of
this test.
4. After a few moments, a message appears regarding an illegal entry. Press Enter
to clear the message and return to the main menu.
5. When your telephone rings, answer the call. You should hear the sound of a
telephone being dialed. This is your computer trying to page you.
If this test is successful, call-out is working.
You now need to go back through the “Telephone Number Setup Menu” on
page A-18 to enter the actual telephone numbers your server will use for reporting
problems.
Serial Port Configuration
To configure the serial port on an AIX system, enter the following commands from an
AIX console:
1. Log in as
root
.
2. To find if you have any serial ports already configured, enter:
lsdev -Cc tty
If no serial ports are configured, none are listed. If you wish to configure serial
ports that are not listed, continue with the remaining steps.
3. Identify the serial port(s) with the modem(s).
4. Enter
smit tty
5. Select
add tty
6. Select
RS232
7. Select
Baud rate 96ðð
or higher.
8. Select
login enable
and set the flow control to RTS.
9. Commit the selections and set up any other needed serial ports.
10. Exit SMIT.
Appendix B. Service Processor Setup and Test
B-3
Содержание RS/6000 H50
Страница 1: ...RS 6000 Enterprise Server Model H50 IBM Installation and Service Guide SA38 0547 00...
Страница 16: ...xvi RS 6000 Enterprise Server Model H50 Installation and Service Guide...
Страница 30: ...1 12 RS 6000 Enterprise Server Model H50 Installation and Service Guide...
Страница 130: ...AIX and Physical Location Code Reference Table 3 50 RS 6000 Enterprise Server Model H50 Installation and Service Guide...
Страница 131: ...Chapter 3 Error Code to FRU Index 3 51...
Страница 160: ...5 18 RS 6000 Enterprise Server Model H50 Installation and Service Guide...
Страница 245: ...Chapter 8 Parts Information Chapter 8 Parts Information 8 1...
Страница 290: ...B 4 RS 6000 Enterprise Server Model H50 Installation and Service Guide...
Страница 305: ...expect 8 r or 7 r or 6 r or 4 r or 3 r delay 2 done Appendix C Modem Configurations C 15...
Страница 312: ...C 22 RS 6000 Enterprise Server Model H50 Installation and Service Guide...
Страница 316: ...D 4 RS 6000 Enterprise Server Model H50 Installation and Service Guide...
Страница 324: ...X 8 RS 6000 Enterprise Server Model H50 Installation and Service Guide...
Страница 326: ...X 10 RS 6000 Enterprise Server Model H50 Installation and Service Guide...