Table
3-1 (Page 26 of 26). Firmware Error Codes.
Error Code
Description
Action / Possible Failing FRU
4BA00001
The system support controller cannot
detect the service processor.
Replace the service processor.
4BA80013
NVRAM.
Refer to map 1540 in the system unit's
Service Guide.
4BA10001
SSC sram fail.
Refer to map 1540 in the system unit's
Service Guide.
4BA10002
SSC sram fail.
Refer to map 1540 in the system unit's
Service Guide.
4BA10003
Service Processor Fail.
Replace Service Processor.
4BA10004
Service Processor Firmware Fail.
Restore or update the SP Flash
EPROM.
4BA10005
I
ò
C Path Fail.
1. I/O board. (See notes on 3-1.)
2. CPU Card.
3. System Board.
Chapter 3. Error Code to FRU Index
3-27
Содержание RS/6000 H50
Страница 1: ...RS 6000 Enterprise Server Model H50 IBM Installation and Service Guide SA38 0547 00...
Страница 16: ...xvi RS 6000 Enterprise Server Model H50 Installation and Service Guide...
Страница 30: ...1 12 RS 6000 Enterprise Server Model H50 Installation and Service Guide...
Страница 130: ...AIX and Physical Location Code Reference Table 3 50 RS 6000 Enterprise Server Model H50 Installation and Service Guide...
Страница 131: ...Chapter 3 Error Code to FRU Index 3 51...
Страница 160: ...5 18 RS 6000 Enterprise Server Model H50 Installation and Service Guide...
Страница 245: ...Chapter 8 Parts Information Chapter 8 Parts Information 8 1...
Страница 290: ...B 4 RS 6000 Enterprise Server Model H50 Installation and Service Guide...
Страница 305: ...expect 8 r or 7 r or 6 r or 4 r or 3 r delay 2 done Appendix C Modem Configurations C 15...
Страница 312: ...C 22 RS 6000 Enterprise Server Model H50 Installation and Service Guide...
Страница 316: ...D 4 RS 6000 Enterprise Server Model H50 Installation and Service Guide...
Страница 324: ...X 8 RS 6000 Enterprise Server Model H50 Installation and Service Guide...
Страница 326: ...X 10 RS 6000 Enterprise Server Model H50 Installation and Service Guide...