MAP 1540: Minimum Configuration
Notes:
1. Be sure to unplug the power cable before removing or installing processor
card(s), memory card(s), system board or I/O board to avoid damage to them.
2. This MAP assumes that a CD-ROM drive is installed and connected to the
integrated SCSI adapter, and a Diagnostics CD-ROM is available.
3. If a power-on password or privileged-access password is installed, you are
prompted to enter the password before the diagnostic CD-ROM can load.
4. The term "POST indicators" refer to the icons (graphic display) or device
mnemonics (ASCII terminal) that appear during the power-on self-test (POST).
5. The Service Processor may have recorded one or more symptoms in its error
log. It is a good idea to examine that error log before proceeding (see Service
Processor System Information Menu).
6. The Service Processor may have been set by the user to monitor server
operations and to attempt recoveries. You may wish to disable these actions
while you diagnose and service the system. If you disable them, you should
make notes of their current settings for restoration before you leave. Following
are the settings of your interest.
Purpose of this MAP
This MAP is used to locate defective FRUs not found by normal diagnostics. For this
procedure, diagnostics are run on a minimally-configured system. If a failure is
detected on the minimally-configured system, the remaining FRUs are exchanged
one at a time until the failing FRU is identified. If a failure is not detected, FRUs are
added back until the failure occurs. The failure is then isolated to the failing FRU.
Surveillance
From the Service Processor Setup Menu, go to
the Surveillance Setup Menu and disable
surveillance.
Unattended Start
From the Service Processor System Power
Control Menu disable unattended start mode.
Reboot Policy
From the System Power Control Menu go to the
Reboot/Restart Policy Setup Menu and set:
1. Number of reboot attempts to 0 (zero)
2. Use OS-Defined restart policy to No
3. Enable supplemental restart policy to No.
Call Out
From the Call-In/Call-Out Setup Menu, go to the
Serial Port Selection Menu and disable call-out
on both serial ports.
Chapter 2. Maintenance Analysis Procedures
2-31
Содержание RS/6000 7043 260
Страница 1: ...RS 6000 7043 Model 260 IBM Service Guide SA38 0554 00...
Страница 6: ...vi Service Guide...
Страница 10: ...x Service Guide...
Страница 14: ...xiv Service Guide...
Страница 16: ...xvi Service Guide...
Страница 18: ...xviii Service Guide...
Страница 20: ...Rear View 1 2 3 4 5 6 7 8 9 11 12 13 14 15 16 10 17 18 19 1 2 Service Guide...
Страница 92: ...2 60 Service Guide...
Страница 198: ...3 To remove the rear cover lift the cover up and away from the system 7 6 Service Guide...
Страница 200: ...b Slide the covers to the rear and remove 7 8 Service Guide...
Страница 220: ...3 Locate the battery on the I O board Battery P N 15F8409 7 28 Service Guide...
Страница 237: ...Chapter 8 Parts Information Chapter 8 Parts Information 8 1...
Страница 238: ...1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 21 20 22 23 24 25 8 2 Service Guide...
Страница 306: ...error Handle unexpected modem responses expect 8 r or 7 r or 6 r or 4 r or 3 r delay 2 done A 62 Service Guide...
Страница 312: ...B 6 Service Guide...
Страница 318: ...X 6 Service Guide...
Страница 321: ......