Step 1240-11
The memory module(s) (may be both) you exchanged in the previous step may be
defective. To isolate the failing memory module, do the following:
1. Turn the power off.
2. Re-install one of the memory modules you exchanged in the previous step.
3. Turn the power on.
Does the system stop with a memory checkpoint displayed on the operator
panel?
NO
Repeat this step with the second memory module you exchanged in the
previous step.
If both memory modules have been tested go to "Map 0410: Repair
Checkout" in the
IBM RS/6000 Diagnostic Information for Multiple Bus
Systems.
YES
Replace the memory module.
If you have not tested both memory modules repeat this step with the
second memory module you exchanged in the previous step.
If the symptom did not change and both memory modules have been
exchanged, go to “Step 1240-10” on page 2-21.
2-22
Service Guide
Содержание RS/6000 7043 260
Страница 1: ...RS 6000 7043 Model 260 IBM Service Guide SA38 0554 00...
Страница 6: ...vi Service Guide...
Страница 10: ...x Service Guide...
Страница 14: ...xiv Service Guide...
Страница 16: ...xvi Service Guide...
Страница 18: ...xviii Service Guide...
Страница 20: ...Rear View 1 2 3 4 5 6 7 8 9 11 12 13 14 15 16 10 17 18 19 1 2 Service Guide...
Страница 92: ...2 60 Service Guide...
Страница 198: ...3 To remove the rear cover lift the cover up and away from the system 7 6 Service Guide...
Страница 200: ...b Slide the covers to the rear and remove 7 8 Service Guide...
Страница 220: ...3 Locate the battery on the I O board Battery P N 15F8409 7 28 Service Guide...
Страница 237: ...Chapter 8 Parts Information Chapter 8 Parts Information 8 1...
Страница 238: ...1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 21 20 22 23 24 25 8 2 Service Guide...
Страница 306: ...error Handle unexpected modem responses expect 8 r or 7 r or 6 r or 4 r or 3 r delay 2 done A 62 Service Guide...
Страница 312: ...B 6 Service Guide...
Страница 318: ...X 6 Service Guide...
Страница 321: ......