4. Either the CD-ROM drive, SCSI adapter, the graphics adapter, or the I/O board
is most likely defective. A tty terminal attached to the serial port also can be used
to also can be used to determine if the graphics adapters is causing the problem.
This is done by removing the graphics adapter, attaching a tty to the serial, and
retrying standalone diagnostics. If the standalone diagnostics load, the graphic
adapter should be replaced.
If the CD-ROM drive is attached to a SCSI adapter card rather than the
integrated SCSI adapter on the I/O board.
– Replace SCSI adapter.
Replace I/O board.
If you replaced the indicated FRUs and the problem is still not corrected, or
the above descriptions did not address your particular situation, go to“MAP
1540: Minimum Configuration” on page 2-31.
Go to "MAP 0410: Repair Checkout" in the
IBM RS/6000 Diagnostic
Information for Multiple Bus Systems.
3-50
Service Guide
Содержание RS/6000 7043 260
Страница 1: ...RS 6000 7043 Model 260 IBM Service Guide SA38 0554 00...
Страница 6: ...vi Service Guide...
Страница 10: ...x Service Guide...
Страница 14: ...xiv Service Guide...
Страница 16: ...xvi Service Guide...
Страница 18: ...xviii Service Guide...
Страница 20: ...Rear View 1 2 3 4 5 6 7 8 9 11 12 13 14 15 16 10 17 18 19 1 2 Service Guide...
Страница 92: ...2 60 Service Guide...
Страница 198: ...3 To remove the rear cover lift the cover up and away from the system 7 6 Service Guide...
Страница 200: ...b Slide the covers to the rear and remove 7 8 Service Guide...
Страница 220: ...3 Locate the battery on the I O board Battery P N 15F8409 7 28 Service Guide...
Страница 237: ...Chapter 8 Parts Information Chapter 8 Parts Information 8 1...
Страница 238: ...1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 21 20 22 23 24 25 8 2 Service Guide...
Страница 306: ...error Handle unexpected modem responses expect 8 r or 7 r or 6 r or 4 r or 3 r delay 2 done A 62 Service Guide...
Страница 312: ...B 6 Service Guide...
Страница 318: ...X 6 Service Guide...
Страница 321: ......