RAID Configuration functions
The IPSSEND RAID configuration functions include the following:
devinfo
Use the devinfo function to retrieve information (such as size and
state) about a specific device.
Supported operating systems: Windows NT, Windows 2000, OS/2,
NetWare, Linux, OpenServer, UnixWare, and DOS
Command: ipssend devinfo controller channel sid
where:
v
controller is the ServeRAID controller number (1–12)
v
channel is the channel number for the device (1, 2, 3, or 4)
v
sid is the SCSI ID for the device (0–15)
drivever
Use the drivever function to display the vendor ID, microcode
version, and serial number of a SCSI device. The IPSSEND
program retrieves this information directly from the device.
Supported operating systems: Windows NT, Windows 2000, OS/2,
NetWare, Linux, OpenServer, UnixWare, and DOS
Command: ipssend drivever controller channel sid
where:
v
controller is the ServeRAID controller number (1–12)
v
channel is the channel number for the device (1, 2, 3, or 4)
v
sid is the SCSI ID for the device (0–15)
getconfig
Use the getconfig function to display the ServeRAID controller
configuration information. This includes information about the
firmware version; initiator ID and rebuild rate; logical-drive status,
RAID level, and size; and physical device type, SCSI ID, and PFA
error.
Supported operating systems: Windows NT, Windows 2000, OS/2,
NetWare, Linux, OpenServer, UnixWare, and DOS
Command: ipssend getconfig controller options
where:
v
controller is the ServeRAID controller number (1–12)
v
options is one of the following:
– AD for the controller information
– LD for the logical drive information
– PD for the physical device information
– AL for all information. This is the default option.
hsrebuild
Use the hsrebuild function to turn on the ServeRAID controller
hot-swap rebuild feature or display the current status of the
hot-swap rebuild feature.
Supported operating systems: Windows NT, Windows 2000, OS/2,
NetWare, Linux, OpenServer, UnixWare, and DOS
Command: ipssend hsrebuild controller options
where:
v
controller is the ServeRAID controller number (1–12)
v
options is one of the following:
– ON enables the hot-swap feature
– ? displays the status of the hot-swap rebuild feature.
122
IBM
®
Netfinity
®
User’s Reference: ServeRAID
™
-4H Ultra160 SCSI Controller
Содержание Netfinity ServeRAID-4H Ultra160
Страница 1: ...IBM Netfinity User s Reference ServeRAID 4H Ultra160 SCSI Controller SC00 N913 20...
Страница 2: ......
Страница 3: ...IBM Netfinity User s Reference ServeRAID 4H Ultra160 SCSI Controller SC00 N913 20...
Страница 12: ...x IBM Netfinity User s Reference ServeRAID 4H Ultra160 SCSI Controller...
Страница 26: ...12 IBM Netfinity User s Reference ServeRAID 4H Ultra160 SCSI Controller...
Страница 74: ...60 IBM Netfinity User s Reference ServeRAID 4H Ultra160 SCSI Controller...
Страница 86: ...72 IBM Netfinity User s Reference ServeRAID 4H Ultra160 SCSI Controller...
Страница 90: ...76 IBM Netfinity User s Reference ServeRAID 4H Ultra160 SCSI Controller...
Страница 92: ...78 IBM Netfinity User s Reference ServeRAID 4H Ultra160 SCSI Controller...
Страница 106: ...92 IBM Netfinity User s Reference ServeRAID 4H Ultra160 SCSI Controller...
Страница 114: ...100 IBM Netfinity User s Reference ServeRAID 4H Ultra160 SCSI Controller...
Страница 120: ...106 IBM Netfinity User s Reference ServeRAID 4H Ultra160 SCSI Controller...
Страница 191: ......