Chapter 7. Solving problems
137
On
MEM
A memory error occurred.
1. Check the DIMM error LEDs on
the memory board.
2. Replace the DIMM indicated by
the lit DIMM error LED.
On
CPU
One of the microprocessors has
failed, or a microprocessor is installed
in the wrong connector.
1. Check the microprocessor error
LEDs on the memory board. If a
microprocessor error LED is on
for a microprocessor connector
that has a terminator card
installed instead of a
microprocessor, the
microprocessors are not installed
in the correct order. See
“Installing a microprocessor kit”
on page 84 for information about
the correct order for installing
microprocessors and VRMs.
Otherwise, continue with the next
step.
2. Turn off the server, reseat the
microprocessor indicated by the
lit microprocessor error LED, and
restart the server.
3. If the problem persists, replace
the microprocessor.
If the problem persists, have the
system serviced.
On
VRM
One of the voltage regulator modules
on the processor board has failed.
1. Check the VRM error LEDs on
the processor board.
2. Turn off the server, reseat the
VRM indicated by the lit VRM
error LED, and restart the server.
3. If the problem persists, replace
the VRM.
If the problem persists, replace the
VRM.
On
FAN
One of the fan assemblies has failed
or is operating too slowly.
Note: A failing fan can also cause
the TEMP and DASD LEDs to
be on.
The LED on the failing fan assembly
will be lit. Replace the fan assembly.
On
TEMP
The system temperature has
exceeded the maximum rating.
1. Check to see if a fan has failed. If
it has, replace the fan.
2. Make sure the room temperature
is not too high. See “Server
specifications” on page 2
3. Check for blocked air flow.
If the problem persists, have the
system serviced.
System error
LED (on the
information LED
panel)
Diagnostics
panel LED on
Cause
Action
Table 18. Light path diagnostics
Содержание Netfinity 7100
Страница 1: ...IBM IBM Netfinity 7100 User s Reference SC19 K081 10 ...
Страница 2: ......
Страница 3: ...IBM IBM Netfinity 7100 User s Reference SC19 K081 10 ...
Страница 7: ...Contents v Index 183 ...
Страница 8: ...vi IBM Netfinity 7100 User s Reference ...
Страница 13: ...xi Statement 4 18 kg 37 lbs 32 kg 70 5 lbs 55 kg 121 2 lbs CAUTION Use safe practices when lifting ...
Страница 34: ...20 IBM Netfinity 7100 User s Reference ...
Страница 72: ...58 IBM Netfinity 7100 User s Reference ...
Страница 174: ...160 IBM Netfinity 7100 User s Reference ...
Страница 196: ...182 IBM Netfinity 7100 User s Reference ...
Страница 199: ......