116
IBM® Netfinity® 7100 User’s Reference
604
An error occurred during a diskette drive test.
Action:
1. Verify that the Configuration/Setup Utility program correctly reflects the type of
diskette drive that you have installed.
2. Run the diagnostic tests. If the diagnostic tests fail, call for service.
662
A diskette drive configuration error occurred.
Action:
If you removed a diskette drive, make sure that the diskette drive setting is correct in
the Configuration/Setup Utility program. If the setting is not correct, change it.
If the problem persists, call for service.
962
A parallel port configuration error occurred.
Action:
If you changed a hardware option, make sure that the parallel port setting is correct in
the Configuration/Setup Utility program. If the setting is not correct, change it.
If the problem persists, call for service.
11xx
An error occurred during the system-board serial port test.
Action:
If you have a modem, serial printer, or other serial device attached to your server,
verify that the serial cable is connected correctly. If it is, use the following procedure:
1. Turn off the server.
2. Disconnect the serial cable from the serial port.
3. Wait five seconds; then, turn on the server.
If the POST error message does not reappear, either the serial cable or the device is probably
failing. See the documentation that comes with the serial device for additional testing information.
If the POST error message reappears, call for service.
1162
The serial port configuration conflicts with another device in the system.
Action:
1. Make sure the IRQ and I/O port assignments needed by the serial port are
available.
2. If all interrupts are being used by adapters, you might need to remove an adapter
to make an interrupt available to the serial port, or force other adapters to share
an interrupt.
1301
Cable to Information LED panel not detected.
Action:
Make sure that the cable to the operator information panel is connected.
If the problem persists, call for service.
1302
Cable to Power and Reset pushbuttons not detected.
Action:
Make sure that the cable to the Power and Reset pushbuttons is connected.
If the problem persists, call for service.
1303
I2C cable to Power Backplane not detected.
Action:
Make sure that the cable to the power backplane is connected.
If the problem persists, call for service.
1304
Cable to Diagnostic LED panel not detected.
Action:
Make sure that the cable to the diagnostic LED panel is connected.
If the problem persists, call for service.
POST message
Description
Table 16. POST error messages
Содержание Netfinity 7100
Страница 1: ...IBM IBM Netfinity 7100 User s Reference SC19 K081 10 ...
Страница 2: ......
Страница 3: ...IBM IBM Netfinity 7100 User s Reference SC19 K081 10 ...
Страница 7: ...Contents v Index 183 ...
Страница 8: ...vi IBM Netfinity 7100 User s Reference ...
Страница 13: ...xi Statement 4 18 kg 37 lbs 32 kg 70 5 lbs 55 kg 121 2 lbs CAUTION Use safe practices when lifting ...
Страница 34: ...20 IBM Netfinity 7100 User s Reference ...
Страница 72: ...58 IBM Netfinity 7100 User s Reference ...
Страница 174: ...160 IBM Netfinity 7100 User s Reference ...
Страница 196: ...182 IBM Netfinity 7100 User s Reference ...
Страница 199: ......