114
IBM® Netfinity® 7100 User’s Reference
184
The power-on password information stored in your server has been removed.
Action:
From the Configuration/Setup Utility program main menu, select System Security.
Then, follow the instructions on the screen.
If this information cannot be restored, call for service.
185
A power failure damaged the stored information about the drive-startup sequence.
Action:
From the Configuration/Setup Utility program main menu, select Start Options; then,
follow the instructions on the screen.
If this information cannot be restored, call for service.
186
A system board or hardware error occurred.
Action:
Call for service.
187
The VPD serial number is not set.
Action:
The system serial number is set in the VPD EEPROM at the time of manufacturing. If
the system board has been replaced, the system serial number will be invalid and
should be set. From the main menu of the Configuration/Setup Utility program, select
System Information, then select Product Data. If the problem persists, call for
service.
188
A vital product data (VPD) error occurred.
Action:
Call for service.
189
An attempt has been made to access the server with invalid passwords. After three incorrect
attempts, the server locks up; that is, the logon data fields are no longer available to the user.
201
An error occurred during the memory controller test. This error can be caused by:
• Incorrectly installed memory
• A failing memory module
• A processor-board problem
• A memory-board problem
Action:
1. If you just installed memory, verify that the new memory is correct for your server.
Also verify that the memory is installed and seated correctly.
2. If the problem persists, check to see if the system has isolated the problem to a
memory module:
• If the System Error light on the operator information panel is on, check to see
if the MEM LED on the diagnostic LED panel is on. If it is on, check the
DIMM Error LEDs next to the memory sockets. If a DIMM Error LED is on,
run the diagnostic program for the memory.
• If the tests fail, replace the DIMM. If the problem persists after you replace
the DIMM, call for service.
• If the memory tests do not fail, call for service.
3. If no error LED is on, the error logs in the Configuration/Setup Utility program
might provide additional information on the memory error.
If the problem persists, call for service.
POST message
Description
Table 16. POST error messages
Содержание Netfinity 7100
Страница 1: ...IBM IBM Netfinity 7100 User s Reference SC19 K081 10 ...
Страница 2: ......
Страница 3: ...IBM IBM Netfinity 7100 User s Reference SC19 K081 10 ...
Страница 7: ...Contents v Index 183 ...
Страница 8: ...vi IBM Netfinity 7100 User s Reference ...
Страница 13: ...xi Statement 4 18 kg 37 lbs 32 kg 70 5 lbs 55 kg 121 2 lbs CAUTION Use safe practices when lifting ...
Страница 34: ...20 IBM Netfinity 7100 User s Reference ...
Страница 72: ...58 IBM Netfinity 7100 User s Reference ...
Страница 174: ...160 IBM Netfinity 7100 User s Reference ...
Страница 196: ...182 IBM Netfinity 7100 User s Reference ...
Страница 199: ......