To
install
a
DIMM,
complete
the
following
steps.
Note:
The
following
illustration
shows
how
to
install
a
DIMM
in
the
blade
server
or
the
MPE
unit.
Retaining
clip
DIMM
1.
Read
the
documentation
that
comes
with
the
DIMM.
2.
Locate
the
DIMM
connectors
(see
“System
board
connectors”
on
page
7).
Determine
the
connectors
into
which
you
will
install
the
DIMMs.
3.
Touch
the
static-protective
package
that
contains
the
DIMM
to
any
unpainted
metal
surface
on
the
BladeCenter
unit
or
any
unpainted
metal
surface
on
any
other
grounded
rack
component;
then,
remove
the
DIMM
from
the
package.
Attention:
To
avoid
breaking
the
DIMM
retaining
clips
or
damaging
the
DIMM
connectors,
open
and
close
the
clips
gently.
4.
Make
sure
that
both
of
the
connector
retaining
clips
are
in
the
fully
open
position.
5.
Turn
the
DIMM
so
that
the
DIMM
keys
align
correctly
with
the
connector
on
the
system
board.
6.
Insert
the
DIMM
by
pressing
the
DIMM
along
the
guides
into
the
connector.
Make
sure
that
the
retaining
clips
snap
into
the
closed
positions.
Attention:
If
there
is
a
gap
between
the
DIMM
and
the
retaining
clips,
the
DIMM
has
not
been
correctly
installed.
In
this
case,
open
the
retaining
clips
and
remove
the
DIMM;
then,
reinsert
the
DIMM.
7.
Install
the
MPE
unit,
if
one
was
removed
while
removing
the
DIMMs
(see
“Installing
an
expansion
unit”
on
page
71).
8.
Install
the
blade
server
cover
(see
“Installing
the
blade
server
cover”
on
page
69).
9.
Install
the
blade
server
into
the
BladeCenter
unit
(see
“Installing
the
blade
server
in
a
BladeCenter
unit”
on
page
66).
Chapter
4.
Removing
and
replacing
blade
server
components
77
Содержание LS21 - BladeCenter - 7971
Страница 1: ...BladeCenter LS21 Type 7971 and LS41 Type 7972 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...BladeCenter LS21 Type 7971 and LS41 Type 7972 Problem Determination and Service Guide...
Страница 8: ...vi BladeCenter LS21 Type 7971 and LS41 Type 7972 Problem Determination and Service Guide...
Страница 16: ...xiv BladeCenter LS21 Type 7971 and LS41 Type 7972 Problem Determination and Service Guide...
Страница 78: ...62 BladeCenter LS21 Type 7971 and LS41 Type 7972 Problem Determination and Service Guide...
Страница 116: ...100 BladeCenter LS21 Type 7971 and LS41 Type 7972 Problem Determination and Service Guide...
Страница 128: ...112 BladeCenter LS21 Type 7971 and LS41 Type 7972 Problem Determination and Service Guide...
Страница 129: ......
Страница 130: ...Part Number 24R9695 Printed in USA 1P P N 24R9695...