The
BMC
log
indicates
an
assertion
event
when
an
event
has
occurred.
It
indicates
a
deassertion
event
when
the
event
is
no
longer
occurring.
Some
of
the
error
codes
and
messages
in
the
BMC
log
are
abbreviated.
You
can
view
the
contents
of
the
BMC
log
from
the
Configuration/Setup
Utility
program
and
from
the
diagnostic
programs.
When
you
are
troubleshooting
PCI-X
slots,
note
that
the
error
logs
report
the
PCI-X
buses
numerically.
The
numerical
assignments
vary
depending
on
the
configuration.
You
can
check
the
assignments
by
running
the
Configuration/Setup
Utility
program
(see
the
Installation
and
User’s
Guide
for
more
information).
Viewing
the
BMC
log
from
the
Configuration/Setup
Utility
program
For
complete
information
about
using
the
Configuration/Setup
Utility
program,
see
the
Installation
and
User’s
Guide
.
To
view
the
BMC
log,
complete
the
following
steps:
1.
Turn
on
the
blade
server.
2.
When
the
prompt
Press
F1
for
Configuration/Setup
appears,
press
F1.
If
you
have
set
a
power-on
password,
you
must
type
the
password
and
press
Enter
to
start
the
Configuration/Setup
Utility
program.
3.
Select
Advanced
Settings
,
select
Baseboard
Management
Controller
(BMC)
settings
,
and
then
select
BMC
System
Event
Log
.
Viewing
the
BMC
log
from
the
diagnostic
programs
The
BMC
log
contains
the
same
information,
whether
it
is
viewed
from
the
Configuration/Setup
Utility
program
or
from
the
diagnostic
programs.
For
information
about
using
the
diagnostic
programs,
see
“Running
the
diagnostic
programs”
on
page
43.
To
view
the
BMC
log,
complete
the
following
steps:
1.
If
the
blade
server
is
running,
turn
off
the
blade
server.
2.
Turn
on
the
blade
server.
3.
When
the
prompt
F2
for
Diagnostics
appears,
press
F2.
4.
From
the
top
of
the
screen,
select
Hardware
Info
.
5.
From
the
list,
select
BMC
Log
.
Chapter
2.
Diagnostics
23
Содержание LS21 - BladeCenter - 7971
Страница 1: ...BladeCenter LS21 Type 7971 and LS41 Type 7972 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...BladeCenter LS21 Type 7971 and LS41 Type 7972 Problem Determination and Service Guide...
Страница 8: ...vi BladeCenter LS21 Type 7971 and LS41 Type 7972 Problem Determination and Service Guide...
Страница 16: ...xiv BladeCenter LS21 Type 7971 and LS41 Type 7972 Problem Determination and Service Guide...
Страница 78: ...62 BladeCenter LS21 Type 7971 and LS41 Type 7972 Problem Determination and Service Guide...
Страница 116: ...100 BladeCenter LS21 Type 7971 and LS41 Type 7972 Problem Determination and Service Guide...
Страница 128: ...112 BladeCenter LS21 Type 7971 and LS41 Type 7972 Problem Determination and Service Guide...
Страница 129: ......
Страница 130: ...Part Number 24R9695 Printed in USA 1P P N 24R9695...