Lit blade-error
LED
Cause
Action
DIMM x error
A memory error occurred.
1. Reseat the DIMM indicated by the lit DIMM
failure LED.
2. Replace the DIMM.
Note:
Multiple DIMM LEDs do not necessarily
indicate multiple DIMM failures. If more than
one DIMM LED is on, reseat/replace one
DIMM at a time until error goes away. Refer to
the BladeCenter management module system
error log for further isolation.
Processor x error
The microprocessor has failed.
1. Verify that the microprocessor indicated by
the lit LED is installed correctly. (See
“Installing an additional microprocessor” on
page 41 for installation instructions).
2. Replace the microprocessor.
Temperature error
The system temperature has exceeded a
threshold level.
1. Check to see if a blower on the
BladeCenter unit has failed. If it has,
replace the fan.
2. Make sure the room temperature is not too
high. (See “Features and specifications” on
page 5 for temperature information.)
System board
error
The system board has failed
1. Replace the blade server cover, reinsert
the blade server in the BladeCenter unit,
and then restart the server.
2. Replace the system board.
IDE bus x error
The IDE bus indicated by the error LED has
failed.
1. Reseat/replace the hard disk drive on IDE
bus
x
.
2. Replace the system board.
NMI error
The system board has failed.
1. Replace the blade server cover, reinsert
the blade server in the BladeCenter unit,
and then restart the blade server.
2. Check the system error log for information
about the error.
If the problem remains, replace the system
board.
Processor
mismatch
The processors do not match.
v
Verify that microprocessors 1 and 2 have
the same cache size and type and the same
clock speed. Internal and external clock
frequencies must be identical; also see
“Error symptoms” on page 77.
76
BladeCenter HS20 Type 8832: Hardware Maintenance Manual and Troubleshooting Guide
Содержание eServer BladeCenter HS20 Type 8832
Страница 1: ...BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 2: ......
Страница 3: ...BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 6: ...iv BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 10: ...viii BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 18: ...8 BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 64: ...54 BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 66: ...56 BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 118: ...108 BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 119: ...Appendix B Safety information 109 ...
Страница 120: ...110 BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 121: ...Appendix B Safety information 111 ...
Страница 122: ...112 BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 123: ...Appendix B Safety information 113 ...
Страница 124: ...114 BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 136: ...126 BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 137: ...Appendix B Safety information 127 ...
Страница 138: ...128 BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 139: ...Appendix B Safety information 129 ...
Страница 140: ...130 BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 141: ...Appendix B Safety information 131 ...
Страница 146: ...136 BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 152: ...142 BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 156: ...146 BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 157: ......
Страница 158: ... Part Number 49Y0165 Printed in USA 1P P N 49Y0165 ...