Note:
See “System” on page 94 to determine which components should be replaced by a field service technician.
Error code/symptom
FRU/action
166-201-003 System Management: Failed
(I2C bus error(s) See SERVPROC and
DIAGS entries in event log.)
1.
I/O adapter
2. System board
166-201-004 System Management: Failed
(I2C bus error(s) See SERVPROC and
DIAGS entries in event log.)
1.
SCSI storage expansion unit
2. System board
166-201-005 System Management: Failed
(I2C bus error(s) See SERVPROC and
DIAGS entries in event log.)
1.
DIMMs
2. Microprocessors
3. System board
166-342-000 System Management: Failed
(ASM adapter BIST indicate failed tests.)
1.
Ensure the latest firmware levels for Remote Supervisor
Adapter and BIOS are installed.
2. Power down blade server and reseat it in chassis.
3. Remote Supervisor Adapter.
166-400-000 System Management: Failed
(ISMP self test result failed tests:
x
where
x
= Flash, RAM, or ROM.)
1.
Reflash or update firmware for ISMP.
2. System board.
180-XXX-000
(Diagnostics LED failure)
v
Run diagnostics panel LED test for the failing LED.
180-XXX-001
(Failed front LED panel test)
1.
Front bezel with customer interface card
2. System board
180-XXX-002
(Failed diagnostics LED panel test)
v
System board
180-XXX-003
(Failed system board LED test)
v
System board
180-XXX-005
(Failed SCSI backplane LED test)
1.
SCSI storage expansion unit
2. System board
201-XXX-0nn
(Failed memory test.)
1.
DIMM Location slots 1-4 where
nn
= DIMM location.
Note:
nn
1=DIMM 1; 2=DIMM 2; 3=DIMM 3; 4=DIMM 4.
2. System board.
202-XXX-001
(Failed system cache test)
1.
Microprocessor 1
2. System board
202-XXX-002
(Failed system cache test)
1.
Microprocessor 2
2. System board
217-198-XXX
(Could not establish drive parameters)
v
SCSI storage expansion unit
217-XXX-000
(Failed hard disk drive test)
Note:
If RAID is configured, the hard disk
drive number refers to the RAID logical
array.
v
Hard disk drive 1
217-XXX-001
(Failed hard disk test)
Note:
If RAID is configured, the hard disk
number refers to the RAID logical array.
v
Hard disk drive 2
70
BladeCenter HS20 Type 8832: Hardware Maintenance Manual and Troubleshooting Guide
Содержание eServer BladeCenter HS20 Type 8832
Страница 1: ...BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 2: ......
Страница 3: ...BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 6: ...iv BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 10: ...viii BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 18: ...8 BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 64: ...54 BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 66: ...56 BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 118: ...108 BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 119: ...Appendix B Safety information 109 ...
Страница 120: ...110 BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 121: ...Appendix B Safety information 111 ...
Страница 122: ...112 BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 123: ...Appendix B Safety information 113 ...
Страница 124: ...114 BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 136: ...126 BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 137: ...Appendix B Safety information 127 ...
Страница 138: ...128 BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 139: ...Appendix B Safety information 129 ...
Страница 140: ...130 BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 141: ...Appendix B Safety information 131 ...
Страница 146: ...136 BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 152: ...142 BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 156: ...146 BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 157: ......
Страница 158: ... Part Number 49Y0165 Printed in USA 1P P N 49Y0165 ...