v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
the
parts
listing
in
the
Problem
Determination
and
Service
Guide
to
determine
which
components
are
customer
replaceable
units
(CRU)
and
which
components
are
field
replaceable
units
(FRU).
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only),”
that
step
must
be
performed
only
by
a
trained
service
technician.
Error
code
Description
Action
1800
An
unavailable
PCI
hardware
interrupt
occurred.
1.
Run
the
Configuration/Setup
Utility
program
and
adjust
the
adapter
settings.
2.
Remove
each
adapter
one
at
a
time,
restarting
the
server
each
time,
until
the
problem
is
isolated.
1801
A
PCI
adapter
has
requested
memory
resources
that
are
not
available.
1.
Change
the
order
of
the
adapters
in
the
PCI
slots.
Make
sure
that
the
boot
device
is
positioned
early
in
the
scan
order
(see
the
User’s
Guide
for
information
about
the
scan
order).
2.
Make
sure
that
the
settings
for
the
adapter
and
all
other
adapters
in
the
Configuration/Setup
Utility
program
are
correct.
If
the
memory
resource
settings
are
not
correct,
change
them.
3.
If
all
memory
resources
are
being
used,
remove
an
adapter
to
make
memory
available
to
the
adapter.
Disabling
the
BIOS
on
the
adapter
should
correct
the
error.
See
the
documentation
that
comes
with
the
adapter.
1962
A
hard
disk
drive
does
not
contain
a
valid
boot
sector.
1.
Make
sure
that
a
bootable
operating
system
is
installed.
2.
Run
the
hard
disk
drive
diagnostic
tests
(see
the
Problem
Determination
and
Service
Guide
for
information
about
running
the
diagnostic
tests).
3.
Reseat
the
hard
disk
drive
cable.
4.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
a.
Hard
disk
drive
cable
b.
Hard
disk
drive
c.
(Trained
service
technician
only)
System
board
5962
IDE
CD
or
DVD
drive
configuration
error.
1.
Run
the
Configuration/Setup
Utility
program
and
load
the
default
settings.
2.
Reseat
the
CD
or
DVD
drive
cable.
3.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
a.
CD
or
DVD
drive
cable
b.
CD
or
DVD
drive
c.
(Trained
service
technician
only)
System
board
Chapter
5.
Solving
problems
43
Содержание E Server x 100 Series
Страница 3: ...xSeries 100 Type 8486 Installation Guide ERserver...
Страница 40: ...28 xSeries 100 Type 8486 Installation Guide...
Страница 46: ...34 xSeries 100 Type 8486 Installation Guide...
Страница 50: ...38 xSeries 100 Type 8486 Installation Guide...
Страница 84: ...72 xSeries 100 Type 8486 Installation Guide...
Страница 85: ......