Features
and
specifications
The
following
table
provides
a
summary
of
the
features
and
specifications
of
the
blade
server.
Notes:
v
Power,
cooling,
removable-media
drives,
external
ports,
and
advanced
system
management
are
provided
by
the
BladeCenter
®
unit.
v
The
operating
system
in
the
blade
server
must
provide
USB
support
for
the
blade
server
to
recognize
and
use
the
removable-media
drives
and
front-panel
USB
ports.
The
BladeCenter
unit
uses
USB
for
internal
communications
with
these
devices.
Microprocessor:
Supports
up
to
two
dual-
or
quad-core
Intel
®
Xeon
microprocessors.
Note:
Use
the
Configuration/Setup
Utility
program
to
determine
the
type
and
speed
of
the
microprocessors
in
your
blade
server.
Memory:
v
Dual-channel
DIMMs:
4
DIMM
slots
v
Type:
fully-buffered
double-data
rate
(FB-DDR2),
PC2-5300,
ECC
SDRAM
registered
x4
(Chipkill)
DIMMs
v
Supports
512
MB,
1
GB,
2
GB,
and
4
GB
DIMMs
(as
of
the
date
of
this
publication)
with
up
to
16
GB
of
total
memory
in
the
system
board
v
Additional
memory
support
when
an
optional
IBM
BladeCenter
Memory
and
I/O
Expansion
Blade
is
installed
Drives:
Support
for
up
to
two
internal
small-form-factor
Serial
Attached
SCSI
(SAS)
drives
Predictive
Failure
Analysis
®
(PFA)
alerts:
v
Microprocessor
v
Memory
v
Hard
disk
drives
Electrical
input:
12
V
dc
Integrated
functions:
v
Dual
Gigabit
Ethernet
controllers
v
Expansion
card
interface
v
Local
service
processor:
Baseboard
management
controller
(BMC)
with
Intelligent
Platform
Management
Interface
(IPMI)
firmware
v
ATI
RN-50
ES1000
video
controller
v
LSI
1064E
Serial
Attached
SCSI
(SAS)
controller
v
Light
path
diagnostics
v
RS-485
interface
for
communication
with
the
management
module
v
Automatic
server
restart
(ASR)
v
Serial
over
LAN
(SOL)
v
Redundant
buses
for
communication
with
keyboard,
mouse,
and
removable
media
drives
v
Concurrent
keyboard/video/mouse
(cKVM)
support
when
optional
cKVM
feature
card
is
installed
Environment
(non-NEBS):
v
Air
temperature:
–
Blade
server
on:
10°
to
35°
C
(50°
to
95°
F).
Altitude:
0
to
914
m
(0
to
3000
ft)
–
Blade
server
on:
10°
to
32°
C
(50°
to
90°
F).
Altitude:
914
to
2134
m
(3000
to
7000
ft)
–
Blade
server
off:
-40°
to
60°
C
(-40°
to
140°
F)
v
Humidity:
–
Blade
server
on:
8%
to
80%
–
Blade
server
off:
5%
to
80%
Environment
(NEBS):
v
Air
temperature:
–
Blade
server
on:
5°
to
40°C
(41°
to
104°F).
Altitude:
-60
to
1800
m
(-197
to
5905
ft)
–
Blade
server
on
(short
term):
-5°
to
55°C
(23°
to
131°F).
Altitude:
-60
to
1800
m
(-197
to
5905
ft)
–
Blade
server
on:
5°
to
30°C
(41°
to
86°F).
Altitude:
1800
to
4000
m
(5905
to
13
123
ft)
–
Blade
server
on
(short
term):
-5°
to
45°C
(23°
to
113°F).
Altitude:
1800
to
4000
m
(5905
to
13
123
ft)
–
Blade
server
off:
-40°
to
60°C
(-40°
to
140°F)
v
Humidity:
–
Blade
server
on:
8%
to
85%
–
Blade
server
on
(short
term):
5%
to
90%
but
not
to
exceed
0.024
kg
water/kg
of
dry
air
–
Blade
server
off:
uncontrolled
Note:
“Short
term”
refers
to
a
period
of
not
more
than
96
consecutive
hours
and
a
total
of
not
more
than
15
days
in
1
year.
(This
refers
to
a
total
of
360
hours
in
any
year,
but
no
more
than
15
occurrences
during
that
1-year
period.)
Size:
v
Height:
24.5
cm
(9.7
inches)
v
Depth:
44.6
cm
(17.6
inches)
v
Width:
2.9
cm
(1.14
inches)
v
Maximum
weight:
5.4
kg
(12
lb)
Chapter
1.
Introduction
3
Содержание 8853L6U
Страница 1: ...BladeCenter HS21 Types 1885 and 8853 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...BladeCenter HS21 Types 1885 and 8853 Problem Determination and Service Guide...
Страница 8: ...vi BladeCenter HS21 Types 1885 and 8853 Problem Determination and Service Guide...
Страница 16: ...xiv BladeCenter HS21 Types 1885 and 8853 Problem Determination and Service Guide...
Страница 30: ...14 BladeCenter HS21 Types 1885 and 8853 Problem Determination and Service Guide...
Страница 145: ......
Страница 146: ...Part Number 49Y0053 Printed in USA 1P P N 49Y0053...