Diagnostic
error
codes
The
following
table
describes
the
error
codes
that
the
diagnostic
programs
might
generate
and
suggested
actions
to
correct
the
detected
problems.
If
the
diagnostic
programs
generate
error
codes
that
are
not
listed
in
the
table,
make
sure
that
the
latest
level
of
the
BIOS
code
is
installed.
In
the
error
codes,
x
can
be
any
numeral
or
letter.
However,
if
the
three-digit
number
in
the
central
position
of
the
code
is
000,
195,
or
197,
do
not
replace
a
CRU
or
FRU.
These
numbers
appearing
in
the
central
position
of
the
code
have
the
following
meanings:
000
The
blade
server
passed
the
test.
Do
not
replace
a
CRU
or
FRU.
195
The
Esc
key
was
pressed
to
end
the
test.
Do
not
replace
a
CRU
or
FRU.
197
This
is
a
warning
error,
but
it
does
not
indicate
a
hardware
failure;
do
not
replace
a
CRU
or
FRU.
Take
the
action
that
is
indicated
in
the
Action
column,
but
do
not
replace
a
CRU
or
a
FRU
.
See
the
description
for
Warning
in
the
section
“Diagnostic
text
messages”
on
page
99
for
more
information.
v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
Chapter
3,
“Parts
listing,
Types
1885
and
8853,”
on
page
15
to
determine
which
components
are
CRUs
and
which
components
are
FRUs.
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only),”
that
step
must
be
performed
only
by
a
trained
service
technician.
Error
code
Description
Action
001-292-000
Core
system:
failed/CMOS
checksum
failed.
Load
the
BIOS
default
settings
by
using
the
Configuration/Setup
Utility
program
and
run
the
test
again
(see
the
Installation
and
User’s
Guide
for
your
blade
server).
001-xxx-000
Failed
core
tests.
(Trained
service
technician
only)
Replace
the
system
board
assembly.
001-xxx-001
Failed
core
tests.
(Trained
service
technician
only)
Replace
the
system
board
assembly.
005-xxx-000
Failed
video
test.
(Trained
service
technician
only)
Replace
the
system
board
assembly.
030-xxx-000
Failed
internal
SAS
interface
test.
(Trained
service
technician
only)
Replace
the
system
board
assembly.
035-xxx-099
No
adapters
were
found.
Reseat
the
adapter
(if
installed).
075-xxx-000
Failed
power
supply
test.
Replace
the
power
module
(see
the
Hardware
Maintenance
Manual
and
Troubleshooting
Guide
or
Problem
Determination
and
Service
Guide
for
your
BladeCenter
unit).
100
BladeCenter
HS21
Types
1885
and
8853:
Problem
Determination
and
Service
Guide
Содержание 8853L6U
Страница 1: ...BladeCenter HS21 Types 1885 and 8853 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...BladeCenter HS21 Types 1885 and 8853 Problem Determination and Service Guide...
Страница 8: ...vi BladeCenter HS21 Types 1885 and 8853 Problem Determination and Service Guide...
Страница 16: ...xiv BladeCenter HS21 Types 1885 and 8853 Problem Determination and Service Guide...
Страница 30: ...14 BladeCenter HS21 Types 1885 and 8853 Problem Determination and Service Guide...
Страница 145: ......
Страница 146: ...Part Number 49Y0053 Printed in USA 1P P N 49Y0053...