Table
5-9 (Page 2 of 4). Stack-Out Status
Green
(Data Out)
Yellow
(DO/CO
Status)
Green
(Control
Out)
Meaning
Off
On
On
Fault detected in Data Out; Data Out is wrapped.
Cause
Action
Stack cable connected to incorrect port
Make sure that Stack Out
connects to Stack In.
Cable problem
Make sure all cable
connections are secure. Check
the cable for breaks or other
damage. Make sure the cable
length and specifications
comply with the requirements
in “Cable Types and
Distances” on page 1-4.
Replace suspect cables with
known good cables. Allow one
minute after each replacement
for problem to clear.
Hardware failure
Isolate the faulty 8239 and
replace it.
Off
On
Off
Fault detected in both Data Out and Control Out; both are
wrapped.
Cause
Action
Stack cable connected to incorrect port
Make sure that Stack Out
connects to Stack In.
Cable problem
Make sure all cable
connections are secure. Check
the cable for breaks or other
damage. Make sure the cable
length and specifications
comply with the requirements
in “Cable Types and
Distances” on page 1-4.
Replace suspect cables with
known good cables. Allow one
minute after each replacement
for problem to clear.
Hardware failure
Isolate the faulty 8239 and
replace it.
5-12
8239 Setup and User’s Guide
Содержание 8239 Token-Ring Stackable Hub
Страница 1: ...8239 Token Ring Stackable Hub Setup and User s Guide GA27 4209 00...
Страница 2: ......
Страница 3: ...8239 Token Ring Stackable Hub Setup and User s Guide GA27 4209 00...
Страница 8: ...vi 8239 Setup and User s Guide...
Страница 10: ...viii 8239 Setup and User s Guide...
Страница 28: ...1 8 8239 Setup and User s Guide...
Страница 36: ...2 8 8239 Setup and User s Guide...
Страница 70: ...5 18 8239 Setup and User s Guide...
Страница 102: ...7 18 8239 Setup and User s Guide...
Страница 120: ...8 18 8239 Setup and User s Guide...
Страница 135: ......
Страница 139: ......
Страница 140: ...Printed in USA GA27 4209 00...
Страница 141: ...Spine information 8239 Token Ring Stackable Hub Setup and User s Guide...