Table 4-1 (Page 2 of 2). LED Symptom/Fix Table
SYMPTOM
FIX
Two or more hubs that are in the same
backplane of a stack have the Prim LED ON.
The physical stack is segmented into more
than one logical stack, with each having one
or more management hubs. Check for loose
or disconnected Stack Link cables. Replace
the hub with the Prim LED ON that is
logically lowest in the stack. To determine
which is logically lowest, you can look at the
hub interconnect cables to see how they are
attached.
The Expansion Port LED is OFF, although
power is ON and an Expansion Port is
installed.
•
Replace the Expansion Port.
•
Replace the 8237.
The Power LED is OFF.
Verify ac power.
Replace the power supply.
An 8237 Model 002 or Model 003 does not
have either the Prim or the Bkup LED ON.
Verify that the hub is correctly connected to
the other hubs in the stack and that it has
power. If no problem is found, replace the
8237.
An 8237 Model 003, or Model 002 with the
RMON upgrade feature, does not have the
RMON LED ON.
•
Replace the RMON Daughter Board.
•
Replace the 8237.
Содержание 8237
Страница 1: ......
Страница 2: ......
Страница 7: ...vi 8237 Hub Installation and Planning Guide...
Страница 15: ...xiv 8237 Hub Installation and Planning Guide...
Страница 41: ...2 8 8237 Hub Installation and Planning Guide...
Страница 91: ...3 50 8237 Hub Installation and Planning Guide...
Страница 109: ...4 18 8237 Hub Installation and Planning Guide Figure 4 20 8237 Field Replaceable Parts...
Страница 113: ...4 22 8237 Hub Installation and Planning Guide...
Страница 117: ...A 4 8237 Hub Installation and Planning Guide...
Страница 147: ...B 30 8237 Hub Installation and Planning Guide...
Страница 166: ...Part Number 85H8847 Printed in Taiwan 85H8847 GA27 4186 00...