11. Connect one end of the IDE signal cable into the back of the drive and the
other end of the cable into the IDE connector on the system board. For the
location of the IDE connectors, see “System board internal cable connectors”
on page 42.
Note:
Make sure to route the signal cable so that it does not block the air flow
to the rear of the drives or over the microprocessor.
12. Connect a power cable to the back of the drive. The connectors are keyed and
can be inserted only one way.
13. If you have other options to install or remove, do so now.
14. Go to the appropriate section to work with another option, or replace the cover.
See “Replacing the cover” on page 55 for details.
15. Reconnect the external cables and power cords; then turn on the attached
devices and the computer.
Power and signal cables for internal drives:
Your computer uses cables to
connect IDE devices to the power supply and to the system board. The following
cables are provided:
v
Four-wire power cables connect the drives to the power supply. At the end of
these cables are plastic connectors that attach to different drives; these
connectors vary in size. Also, certain power cables attach to the system board.
v
Flat signal cables, also called ribbon cables, connect IDE and diskette drives to
the system board. There are two sizes of ribbon cables that come with your
computer.
– The wider IDE signal cable has two or three connectors.
- If the cable has three connectors, one of these connectors is attached to
the drive, one is a spare, and the third attaches to the primary or secondary
IDE connector on the system board.
- If the cable has two connectors, one of these connectors is attached to the
hard disk drive, and the other attaches to the primary or secondary IDE
connector on the system board.
Note:
The CD-ROM drive will have an ATA 66 signal cable. ATA 66 signal
cables are color-coded. The blue connector attaches to the system
board. The black connector attaches to the primary device. The gray
middle connector attaches to the secondary device. If you are installing
a hard disk drive, you must change the switch setting on the CD-ROM
drive to secondary and change the connector used for the CD-ROM
drive to the gray middle connector.
– The narrower signal cable has two connectors, one to attach to the diskette
drive, and the other to attach to the connector (FDD1) on the system board.
To locate connectors on the system board, see “System board internal cable
connectors” on page 42.
52
IBM IntelliStation E Pro Types 6204 and 6214: User’s Guide
Содержание 620410U - IntelliStation E - Pro 6204
Страница 3: ...IBM IntelliStation E Pro Types 6204 and 6214 User s Guide...
Страница 8: ...vi IBM IntelliStation E Pro Types 6204 and 6214 User s Guide...
Страница 14: ...xii IBM IntelliStation E Pro Types 6204 and 6214 User s Guide...
Страница 16: ...xiv IBM IntelliStation E Pro Types 6204 and 6214 User s Guide...
Страница 26: ...10 IBM IntelliStation E Pro Types 6204 and 6214 User s Guide...
Страница 36: ...20 IBM IntelliStation E Pro Types 6204 and 6214 User s Guide...
Страница 44: ...28 IBM IntelliStation E Pro Types 6204 and 6214 User s Guide...
Страница 54: ...38 IBM IntelliStation E Pro Types 6204 and 6214 User s Guide...
Страница 130: ...114 IBM IntelliStation E Pro Types 6204 and 6214 User s Guide...
Страница 136: ...120 IBM IntelliStation E Pro Types 6204 and 6214 User s Guide...
Страница 138: ...122 IBM IntelliStation E Pro Types 6204 and 6214 User s Guide...
Страница 140: ...124 IBM IntelliStation E Pro Types 6204 and 6214 User s Guide...
Страница 152: ...136 IBM IntelliStation E Pro Types 6204 and 6214 User s Guide...
Страница 158: ...142 IBM IntelliStation E Pro Types 6204 and 6214 User s Guide...
Страница 164: ...148 IBM IntelliStation E Pro Types 6204 and 6214 User s Guide...
Страница 165: ......
Страница 166: ...IBM Part Number 59P5622 Printed in the United States of America 59P5622...