Table 3. Firmware Error Codes. (continued)
Error Code Description
Action / Possible Failing FRU
2BA00012 Service processor reports self-test failure. 1. Unplug the system power cable
and wait until the system power
indicator remains off and the
operator panel is blank.
2. Plug the system power cable back
in and retry the operation.
3. Replace the system board.
Location: P1
(See note 3 on page 109.)
2BA00013 Service processor reports bad NVRAM
CRC.
1. If problem persists, replace
battery.
Location: P1-V2
2. Replace the system board.
Location: P1
(See note 3 on page 109.)
2BA00014 Service processor reports bad service
processor firmware.
Use service processor firmware
diskette to reprogram firmware.
2BA00017 Service processor reports bad or low
battery.
1. Replace the battery.
Location: P1-V2
2. Replace the system board.
Location: P1
(See note 3 on page 109.)
2BA00018 EPOW test failure.
Replace the system board.
Location: P1
(See note 3 on page 109.)
2BA00019 IRQ13 test failure.
Replace the system board.
Location: P1
(See note 3 on page 109.)
2BA00024 Service processor reports bad power
controller firmware.
Use the system firmware diskette to
reprogram the system firmware.
2BA00040 Service processor reports service
processor VPD module not present.
1. Use the service processor
firmware diskette to reprogram the
service processor firmware.
2. Replace the system board.
Location: P1
(See note 3 on page 109.)
2BA00041 Service processor VPD is corrupted.
1. Use the service processor
firmware diskette to reprogram the
service processor firmware.
2. Replace the system board.
Location: P1
(See note 3 on page 109.)
Chapter 5. Error Code to FRU Index
127
Содержание 265
Страница 1: ...IntelliStation POWER 9112 Model 265 Service Guide SA38 0609 00 IBM...
Страница 2: ......
Страница 3: ...IntelliStation POWER 9112 Model 265 Service Guide SA38 0609 00 IBM...
Страница 14: ...xii Service Guide...
Страница 20: ...Fan Locations 1 2 3 4 1 Fan 1 2 Fan 2 3 Fan 3 4 Fan 4 4 Service Guide...
Страница 46: ...30 Service Guide...
Страница 96: ...80 Service Guide...
Страница 190: ...174 Service Guide...
Страница 287: ...Replacement Replace in reverse order Chapter 9 Removal and Replacement Procedures 271...
Страница 308: ...292 Service Guide...
Страница 309: ...Chapter 10 Parts Information This chapter contains parts information for the 9112 Model 265 293...
Страница 310: ...System Parts 1 2 3 4 5 6 7 8 9 10 16 18 17 19 11 12 13 14 15 20 22 21 23 24 25 26 27 29 28 294 Service Guide...
Страница 324: ...308 Service Guide...
Страница 328: ...312 Service Guide...
Страница 347: ...responses expect 8 r or 7 r or 6 r or 4 r or 3 r delay 2 done Appendix D Modem Configurations 331...
Страница 354: ...338 Service Guide...
Страница 363: ......
Страница 364: ...IBM Printed in U S A February 2002 SA38 0609 00...
Страница 365: ...Spine information IBM IntelliStation POWER 9112 Model 265 Service Guide SA38 0609 00...