Table 3. Firmware Error Codes. (continued)
Error Code Description
Action / Possible Failing FRU
450000D2 System bus protocol/transfer error
(checkstop)
1. Replace the FRU as indicated by
the physical location code
displayed on the operator panel.
2. Check the service processor error
log for additional FRUs.
450000D3 I/O host bridge time-out error (checkstop)
1. Replace the FRU as indicated by
the physical location code
displayed on the operator panel.
2. Check the service processor error
log for additional FRUs.
450000D4 I/O host bridge address/data bus parity
error (checkstop)
1. Replace the FRU as indicated by
the physical location code
displayed on the operator panel.
2. Check the service processor error
log for additional FRUs.
450000D6 System support function error (checkstop) 1. Replace the FRU as indicated by
the physical location code
displayed on the operator panel.
2. Check the service processor error
log for additional FRUs.
450000D7 System bus internal hardware/switch
error (checkstop)
1. Replace the FRU as indicated by
the physical location code
displayed on the operator panel.
2. Check the service processor error
log for additional FRUs.
450000DA The processor was found deconfigured.
The service processor reconfigured the
available processor.
1. Note that this error code indicates
that the corresponding FRU has
been reconfigured. Check the
processor config/deconfig menu in
the service processor system
information menu before replacing
parts.
2. Replace the processor card.
Location: P1-C1
Location: P1-C2
450000DB All memory DIMM pairs were found
deconfigured. The service processor
reconfigured the best available pair.
1. Note that this error code indicates
that the corresponding FRU has
been reconfigured. Check the
processor config/deconfig menu in
the service processor system
information menu before replacing
parts.
2. Replace all memory DIMM pairs.
45800000 Memory controller checkstop
Go to “MAP 1540: Minimum
Configuration” on page 59.
Chapter 5. Error Code to FRU Index
153
Содержание 265
Страница 1: ...IntelliStation POWER 9112 Model 265 Service Guide SA38 0609 00 IBM...
Страница 2: ......
Страница 3: ...IntelliStation POWER 9112 Model 265 Service Guide SA38 0609 00 IBM...
Страница 14: ...xii Service Guide...
Страница 20: ...Fan Locations 1 2 3 4 1 Fan 1 2 Fan 2 3 Fan 3 4 Fan 4 4 Service Guide...
Страница 46: ...30 Service Guide...
Страница 96: ...80 Service Guide...
Страница 190: ...174 Service Guide...
Страница 287: ...Replacement Replace in reverse order Chapter 9 Removal and Replacement Procedures 271...
Страница 308: ...292 Service Guide...
Страница 309: ...Chapter 10 Parts Information This chapter contains parts information for the 9112 Model 265 293...
Страница 310: ...System Parts 1 2 3 4 5 6 7 8 9 10 16 18 17 19 11 12 13 14 15 20 22 21 23 24 25 26 27 29 28 294 Service Guide...
Страница 324: ...308 Service Guide...
Страница 328: ...312 Service Guide...
Страница 347: ...responses expect 8 r or 7 r or 6 r or 4 r or 3 r delay 2 done Appendix D Modem Configurations 331...
Страница 354: ...338 Service Guide...
Страница 363: ......
Страница 364: ...IBM Printed in U S A February 2002 SA38 0609 00...
Страница 365: ...Spine information IBM IntelliStation POWER 9112 Model 265 Service Guide SA38 0609 00...