2. Wiring
77
1) Stop supplying external motor power at emergency stop input
Note 1 The rating for the emergency stop signal to turn ON/OFF at contact CR1 is 24V DC
and 10mA or less.
Note 2 Connect such as a connector to L1/L2/L3 terminals when cutting off the motor power
source externally.
(This controller is not equipped with internal drive cutoff relay.)
Note 3 It is the contact output to control the drive cutoff device connected externally. The
rating is 30V DC and 200mA or less. [Refer to 2.6.2 for detail]
Note 4 Connect the temperature sensor contact when external regenerative resistor units are
connected.
2.2.3
Contact Output for
Drive Cutoff
(Note 3)
Circuit for Stop
PC Software Cable or Dummy plug
SIO connector
System I/O connector
Emergency
stop circuit
exclusive
use 24V
Emergency
stop switch
Short-circuit
in PC software cable
CR1
(Note 1)
Emergency
stop reset
switch
Motor power
supply
MC1
(Note 2)
Control power
supply
CR1
(Note 1)
AC power supply input connector
Temperature Sensor Contact for External
Regenerative Resistor Unit
(Note 4)
Содержание SCON-CB-F
Страница 2: ......
Страница 4: ......
Страница 10: ......
Страница 16: ......
Страница 48: ...1 Specifications Check 32 1 3 3 SCON CGB 3000W and above ...
Страница 60: ...1 Specifications Check 44 ...
Страница 266: ...3 Operation 250 ...
Страница 276: ...4 Field Network 260 ...
Страница 282: ...5 Vibration Suppress Control Function 266 ...
Страница 362: ...9 Troubleshooting 346 ...
Страница 444: ...10 Appendix 428 ...
Страница 449: ......