![IAI SCON-CB-F Скачать руководство пользователя страница 292](http://html1.mh-extra.com/html/iai/scon-cb-f/scon-cb-f_instruction-manual_604055292.webp)
7.
Absolute Reset and
Absolute Battery
276
7.2.2 Replacement of Absolute Battery
For the battery replacement, remove the battery connector while keeping the power to the
controller ON, and change the battery installed in the battery holder.
Caution: To replace the old absolute battery with a new one with the controller power being
OFF, complete the replacement within 15 minutes from the removal of the old
battery. The absolute data may get lost if it exceeds 15 minutes.
[Removal]
[Attachment]
Disconnect the
connector and pull
out the battery.
Put battery into
battery holder.
Plug in connector to
absolute battery
connector.