![IAI SCON-CB-F Скачать руководство пользователя страница 124](http://html1.mh-extra.com/html/iai/scon-cb-f/scon-cb-f_instruction-manual_604055124.webp)
2. Wiring
108
[5] PIO Circuit
Use the attached cable for the I/O connection.
Model : CB-PAC-PIO□□□ (□□□ indicates the cable length L. Example. 020 = 2m)
Half Pitch MIL Socket
HIF6-40D-1.27R (Hirose Electric)
Flat Cable (20-core) × 2
L
20A
20B
1A
1B
BK -4 (20B)
Bottom Line
Top Line
BK -2 (20A)
BR -3 (1B)
BR -1 (1A)
No connector
No connector
Caution : When having a conduction check on the flat cable, make sure not to spread out the
inside of the connector female pins. It may cause a contact error and may disable
normal operation.
24V DC
Supply
1A
P24
1B
0V
Supply
2A
P24
2B
3A
X000
X001
X002
X003
X004
X005
X006
X007
X008
X009
X00A
X00B
X00C
X00D
X00E
X00F
Y000
Y001
Y002
Y003
Y004
Y005
Y006
Y007
Y008
Y009
Y00A
Y00B
Y00C
Y00D
Y00E
Y00F
3B
4A
4B
5A
5B
6A
6B
7A
7B
8A
8B
9A
9B
10A
10B
11A
11B
12A
12B
13A
13B
14A
14B
15A
15B
16A
16B
17A
N
17B
18A
N
18B
19A
19B
20A
20B
PIO
Connector
BR- 1
RD- 1
OR- 1
YW- 1
GN- 1
BL- 1
PL- 1
GY- 1
WT- 1
BK- 1
BR- 2
RD- 2
OR- 2
YW- 2
GN- 2
BL- 2
PL- 2
GY- 2
WT- 2
BK- 2
BR- 3
RD- 3
OR- 3
YW- 3
GN- 3
BL- 3
PL- 3
GY- 3
WT- 3
BK- 3
BR- 4
RD- 4
OR- 4
YW- 4
GN- 4
BL- 4
PL- 4
GY- 4
WT- 4
BK- 4
0V(NPN Type)
24V DC(NPN Type)
24V DC(PNP Type)
0V(PNP Type)
“*” in codes above shows the signal of the active low. Processing occurs when an
input signal of the type is turned OFF. An output signal of the type is normally ON
in the power-on status and turned OFF at signal output.
2.4.3
Содержание SCON-CB-F
Страница 2: ......
Страница 4: ......
Страница 10: ......
Страница 16: ......
Страница 48: ...1 Specifications Check 32 1 3 3 SCON CGB 3000W and above ...
Страница 60: ...1 Specifications Check 44 ...
Страница 266: ...3 Operation 250 ...
Страница 276: ...4 Field Network 260 ...
Страница 282: ...5 Vibration Suppress Control Function 266 ...
Страница 362: ...9 Troubleshooting 346 ...
Страница 444: ...10 Appendix 428 ...
Страница 449: ......