2. Wiring
52
2.1.3 Wiring
[1] Main Power Circuit
Surge Protector
Noise Filter
Earth Leakage Breaker
Circuit Breaker
PE
Motor Power Unit
Control Power Supply
L1 L2
L1
L2
L1C
L2C
SCON
Power Supply Input Connector
(Note) The power voltage of the controller (100V AC or 200V AC) cannot be changed.
[2] Brake Power Supply Circuit
(Note) Supply 24V DC if the used actuator is equipped with a brake.
Brake Power Supply Connector
BK PWR
+
-
24V DC
0V
SCON
Grounding resistance at 100Ω or less
(Grounding Class D)