1. Specifications Check
29
1.2.2 Power Capacity and Heat Generation
Rated Power Capacity = Motor Power Ca Control Power Capacity
Peek Max. Power Capacity = Peek Max. Motor Power Ca Control Power Capacity
Actuator Motor
Wattage
Motor Power
Capacity
[VA]
Peek Max. Motor
Power Capacity
[VA]
Control Power
Capacity [VA]
Rated Power
Capacity [VA]
Peek Max. Power
Capacity [VA]
Heat Generation
[W]
12
41
123
89
171
30
20
26
78
74
126
30
30D (Excluding
RS)
46
138
94
186
31
30R (for RS)
138
414
186
462
33
60
138
414
186
462
33
60 (RCS3-CTZ5)
197
591
245
639
32
100
234
702
282
750
35
100S (LSA)
283
851
331
899
36
150
328
984
376
1032
37
200
421
1263
469
1311
38
200S(DD)
503
1509
551
1557
7.5
200S
(Excluding
LSA(S)-N15H)
486
1458
534
1506
38
200S
(LSA(S)-N15H)
773
2319
821
2367
56
300S (LSA)
662
1986
710
2034
40
400
920
2760
968
2808
45
400 (RCS3-CT8)
1230
3690
1278
3738
47
600
1164
2328
1212
2376
56
600(DD)
1462
4386
1510
4434
20.8
750
3042
3090
750S
1521
4563
1569
4611
58
3000
5657
16970
5705
17018
180
3300
6014
18041
48
6062
18099
182
RS : Rotary Shaft, LSA : Linear Actuator, DD : Direct Drive Motor
1.2.3 Selection of Circuit Interrupter
For the selection of the circuit breaker, perform it according to the following items.
• 3 times of the rated current flows to the controller during the acceleration/deceleration. Select an
interrupter that does not trip with this value of current. If a trip occurs, select an interrupter that
possesses the rated current of one grade higher. (Check the operation characteristics curves in
the product catalog.)
• Select an interrupter that does not trip with the in-rush current. (Check the operation
characteristics curves in the product catalog.)
• Consider the current that enables to cutoff the current even when a short circuit current is flown
for the rated cutoff current.
Rated Interrupting Current > Short Circuit Current = Primary Power Capacity / Power Voltage
Consider margin for the rated current on the circuit breaker.
● Calculation for Motors of up to 750W
Rated Current for Circuit Interrupter >
(Rated Motor Power Capacity [VA] + Control Power Capacity [VA]) / AC Input Voltage × Safety Margin
(reference 1.2 to 1.4 times)
● Calculation for Motors of 3000W and abouve
Rated Current for Circuit Interrupter >
(Rated Motor Power Capacity [VA] + Control Power Capacity [VA]) / AC Input Voltage × Safety Margin
(reference 1.2 to 1.4 times)
/
√3
Содержание SCON-CB-F
Страница 2: ......
Страница 4: ......
Страница 10: ......
Страница 16: ......
Страница 48: ...1 Specifications Check 32 1 3 3 SCON CGB 3000W and above ...
Страница 60: ...1 Specifications Check 44 ...
Страница 266: ...3 Operation 250 ...
Страница 276: ...4 Field Network 260 ...
Страница 282: ...5 Vibration Suppress Control Function 266 ...
Страница 362: ...9 Troubleshooting 346 ...
Страница 444: ...10 Appendix 428 ...
Страница 449: ......