3. Operation
169
[7] Binary Output of Alarm Data Output (*ALM, PM1 to 8)
Output
PIO signal
*ALM
PM1 to 8
Common to Patterns
0 to 3
{
{
Pattern 4
(Note 1)
{
×
Pattern 5
(Note 1)
{
×
Pattern 6
{
{
Pattern 7
(Note 1)
{
×
{
: Available,
×
: Unavailable
Note 1 Patterns 4, 5, and 7 do not have this function.
1) If an alarm at a level equal to or higher than the operation release level occurs, completed position
number output signals PM1 to PM8 output the alarm information in the binary code format.
2) The PLC can read the binary code of alarm signal *ALM as the strobe signal to refer to alarm
information.
{
: ON
z
: OFF
*
ALM
ALM8
(PM8)
ALM4
(PM4)
ALM2
(PM2)
ALM1
(PM1)
Binary Code
Description: Alarm code is shown in ( ).
{
z
z
z
z
–
Normal
z
z
z
{
z
2
Software reset during servo ON (090)
Position number error during teaching (091)
PWRT signal detected during movement (092)
PWRT signal detected before completion of home return
(093)
z
z
z
z
{
3
Move command during servo OFF (080)
Position command in incomplete home return (082)
Absolute position move command when home return is not
yet completed (083)
Movement command during home return operation (084)
Position No. error during movement (085)
Move command while pulse train input is effective (086)
Move command during loadcell calibration (087)
Position command data error (0A3)
Command deceleration error (0A7)
z
z
{
z
z
4
FAN error detection (0D6)
Drive mode error (0DD)
Field bus module not detected (0F3)
Mismatched PCB (0F4)
z
z
{
z
{
5
Loadcell data error (0A9)
Loadcell calibration error (0E1)
Loadcell communication error (0E2)
Loadcell error (0E3)
Field bus link error (0F1)
Field bus module error (0F2)
z
z
{
{
z
6
Parameter data error (0A1)
Position data error (0A2)
Unsupported motor/encoder type (0A8)
z
z
{
{
{
7
Z-phase position error (0B5)
Magnetic pole indeterminacy (0B7)
Home sensor non-detection (0BA)
Home return timeout (0BE)
Creep sensor not detected (0BF)
(Note) *ALM Signal is an active low signal. It is ON when the power is applied to the controller, and
turns OFF when the signal is output.
3.2.3
Содержание SCON-CB-F
Страница 2: ......
Страница 4: ......
Страница 10: ......
Страница 16: ......
Страница 48: ...1 Specifications Check 32 1 3 3 SCON CGB 3000W and above ...
Страница 60: ...1 Specifications Check 44 ...
Страница 266: ...3 Operation 250 ...
Страница 276: ...4 Field Network 260 ...
Страница 282: ...5 Vibration Suppress Control Function 266 ...
Страница 362: ...9 Troubleshooting 346 ...
Страница 444: ...10 Appendix 428 ...
Страница 449: ......