8. Parameter
310
[82] Calendar function (Parameter No.111)
No.
Name
Symbol
Unit
Input Range
Default factory
setting
111 Calendar function
FRTC
–
0: Does not use the
calendar timer
1: Use the calendar
timer
1
This parameter defines whether the calendar function (RTC) is used or not.
Set the current time with using a teaching tool when the calendar function is used.
[Refer to the instruction manual of the teaching tool for the details.]
In use of RTC, the alarm occurrence time in the alarm list is the time at which an alarm has
occurred.
If RTC is not used, the time of alarm issuance shown in the alarm list counts the time passed
since the power is supplied to the controller counted as 0 second.
The time data retainable duration with no power supply to the controller is approximately
10 days.
Set Value
Description
0
Not Applicable
1
Use
[83] Monitoring mode (Parameter No.112)
No.
Name
Symbol
Unit
Input Range
Default factory
setting
112 Monitoring mode
FMNT
–
0: Does not use
1: Monitor function 1
2: Monitor function 2
3: Monitor function 3
1
The controller can be connected with PC software to monitor the servo.
This parameter allows you to select a monitoring mode function (servo monitor).
Check the Instruction Manual of the RC PC software for details.
Set Value
Description
0
Unused
1
Sets the 4CH-30000 record mode.
2
Sets the 8CH-15000 record mode.
3
Sets the 2CH-60000 record mode.
Содержание SCON-CB-F
Страница 2: ......
Страница 4: ......
Страница 10: ......
Страница 16: ......
Страница 48: ...1 Specifications Check 32 1 3 3 SCON CGB 3000W and above ...
Страница 60: ...1 Specifications Check 44 ...
Страница 266: ...3 Operation 250 ...
Страница 276: ...4 Field Network 260 ...
Страница 282: ...5 Vibration Suppress Control Function 266 ...
Страница 362: ...9 Troubleshooting 346 ...
Страница 444: ...10 Appendix 428 ...
Страница 449: ......