Chapter 6
Troubleshooting
224
Alarm
Code
Alarm Name
Cause/Treatment
AC
Continuous Regenerative
Excessive Discharge
Cause
: The regenerative electric power exceeded what can be
dealt with the regenerative resistor.
Treatment : Decrease the acceleration/deceleration speed, revise the
operation interval or connect an external optional
regenerative resistor (RER-1).
FF
Power-on Log
It is the log at the power being on (it is not an error).