3.4 Fieldbus
Type
Address Map
103
[4] Address Map for SEP I/O Mode
Shown below is the address map for each Fieldbus when eight axes of MSEP are operated in
SEP I/O Mode.
1) DeviceNet, CompoNet
(n is the top channel number for each PLC input and output between MSEP and PLC)
PLC ĺ MSEP
MSEP ĺ PLC
CH No.
Description
CH No.
Description
n to n+1
Gateway Control
n to n+1
Gateway Status
n+2 to n+7
Demand Command
n+2 to n+7
Response Command
n+8
Axis No.0 to 7 Control
Information
n+8
Axis No.0 to 7 Status
Information
2) CC-Link
(Extended Cyclic Setting/Number of Occupied Stations: 1 times/4 stations)
PLC ĺ MSEP
MSEP ĺ PLC
Address
Description
Address
Description
RY 00 to 1F
Gateway Control
RX 00 to 1F
Gateway Status
RY 20 to 6F
Demand Command
RX 20 to 6F
Response Command
RY 70 to 7F
Cannot be used.
RX 70 to 7F
Cannot be used.
RWw 00
Axis No.0 to 7 Control
Information
RWr 00
Axis No.0 to 7 Status
Information
RWw 01 to 0F
Cannot be used.
RWr 01 to 0F
Cannot be used.
3) PROFIBUS-DP, EtherNet/IP, MECHATROLINK, EtherCAT
(n is the top node address for each PLC input and output between MSEP and PLC)
PLC ĺ MSEP
MSEP ĺ PLC
Node Address
(Byte Address)
Description
Node Address
(Byte Address)
Description
n
to n+
3
G
ateway Control
n
to n+
3
G
ateway Status
n
+
4
to n+
15
D
emand Command
n
+
4
to n+
15
R
esponse Command
n+
16 to n+19
Axis No.0 to 7 Control
Information
n+
16 to n+19
Axis No.0 to 7 Status
Information
Содержание Msep
Страница 1: ...MSEP Controller Instruction Manual Fourth Edition ...
Страница 2: ......
Страница 4: ......
Страница 8: ......
Страница 202: ...3 10 Status LED 194 Note 1 blinking Note 2 single flash Note 3 double flash Timing of LED flashing ...
Страница 244: ...Chapter 6 Troubleshooting 236 ...
Страница 290: ...Chapter 7 Appendix 282 ...
Страница 294: ......
Страница 295: ......