1) FG Terminal Block
This is the terminal block for frame grounding. Since this controller is made of plastic, it is
necessary to ground from this terminal block. Ground Type should be Class D (formally
Class 3 grounding = ground resistance 100ȍ or less).
2) Power Line Input Connector
This is the connector to supply 24V DC power supply to the controller. The control power
supply and the motor power supply are to be input separately. This enables external drive
cutoff that cuts only the motor power supply.
3) Model Code Record Card
This is a card with information of the connected axes recorded on for eight axes at the
maximum. It is available to pull out from the controller and check the information.
4) Drive Cutoff/Emergency Stop Input Connector
External drive cutoff and emergency stop can be performed individually for each slot (2
axes).
5) Compulsory Brake Release Signal Input Connector
An external compulsory brake release can be performed on each axis. The brake is
ordinarily released with the servo ON and activated with the servo OFF. In the tuning at the
startup or in the maintenance work, have a brake release switch for each axis connected to
this connector to make a compulsory brake release available, and the actuator can be
moved manually while the servo is OFF.
6) Absolute Battery Connector
This connector is mounted on the absolute type. An external absolute battery box for eight
axes can be connected with one cable. This is not mounted on the incremental type.
7) Status LEDs for Driver
These lamps indicate the status of the driver and that for absolute type for each slot (in 2
axes unit). There is no absolute status display for the incremental type.
Part Name
Description
SYS I
System status of driver for axis connected to
upper connector
(Servo ON: GN,
Servo OFF: OFF,
Alarm generated: RD)
SYS II
System status of driver for axis connected to
lower connector
(Servo ON: GN,
Servo OFF: OFF,
Alarm generated: RD)
I–0
Absolute status of driver for axis connected
to upper connector 0
I–1
Absolute status of driver for axis connected
to upper connector 1
I–2
Absolute status of driver for axis connected
to upper connector 2
II–0
Absolute status of driver for axis connected
to lower connector 0
II–1
Absolute status of driver for axis connected
to lower connector 1
II–2
Absolute status of driver for axis connected
to lower connector 2
SYS
I II
0
1
2
0
1
2
I
II
Содержание Msep
Страница 1: ...MSEP Controller Instruction Manual Fourth Edition ...
Страница 2: ......
Страница 4: ......
Страница 8: ......
Страница 202: ...3 10 Status LED 194 Note 1 blinking Note 2 single flash Note 3 double flash Timing of LED flashing ...
Страница 244: ...Chapter 6 Troubleshooting 236 ...
Страница 290: ...Chapter 7 Appendix 282 ...
Страница 294: ......
Страница 295: ......