-VS Instruction Manual 

Document No. 

HIM-08004

 

 

 
 

 

5

  / 

16

 

Confidential C                                                                   

注意事項

  / Cautions. / 

注意事项

 

片側ずつ押すと、隙間が発生する恐れが有ります。(図

6

 

 

When you push one end by one end, there is possibility to cause a gap. 

Fig.6

 

如果只按压一侧,有可能产生插入不到位的状况。

(接触面会产生间隙)

6

 

 

 

 

 

 

6

Fig.6

 

 

挿入する際、

PLUG

に下向きの力を入れながら挿入すると、

PCB

に傷が入りパターンが断線したり、ショート

 

したりする可能性がありますので、下向きの力は加えないようにしてください。

 

If you apply downward force from connector above especially edge of pull bar when you insert Plug   

into Receptacle, there is a possibility to damage PCB like picture below. This downward force on edge of   

pull bar will be cause of short and circuit and disconnection of PCB Layout. Therefore, please do not apply   

any load from above. 

在进行插入作业时,在

Plug

的正上方不能施加向下的力,如果施加向下的力,有可能会在

PCB

板上

 

造成伤痕甚至会破坏

PCB

里面的线路。

 

 

 

                 

 

 
 

隙間発生

  NG

状態

 

A gap occurs. NG 

接触面会产生间隙

 

片側挿入

Push the one side. 

只按压一侧

1

 

片側挿入

Push the one side. 

只按压一侧

2

 

NG 

挿入方向

 

Inserting 

direction 

傷発生

Scratch occurred. / 

有伤痕发生

 

Содержание CABLINE-VS

Страница 1: ...T Receptacle 20455 E Instruction Manual 5 S19019 January 8 2019 Y Miyazaki T Masunaga H Ikari 4 S18402 July 2 2018 A Koyanagi T Masunaga H Ikari 3 S17909 December 12 2017 Y Miyazaki T Masunaga H Ikar...

Страница 2: ...nnector Product Name CABLINE VS PLUG Part No 20453 T 1 With PULL BAR 2 Without PULL BAR 3 With INSULATION PULL BAR The PCB side connector Product Name CABLINE VS RECEPTACLE Part No 20455 E part shows...

Страница 3: ...K of the cable connector is upper side I PEX 1 Fig 1 2 How to mate 2 As shown in Fig 2 push both ends of cable side connector horizontally until the lock is locked 2 Plug 2 Fig 2 Push both ends of con...

Страница 4: ...of cable side connector horizontally Then confirm whether there is space between mating confirmation surfaces 3 3 Fig 3 PULL BAR SHELL After mated push PULL BAR to the PCB side and lock it to SHELL o...

Страница 5: ...connector above especially edge of pull bar when you insert Plug into Receptacle there is a possibility to damage PCB like picture below This downward force on edge of pull bar will be cause of short...

Страница 6: ...ULL BAR When mating in case you mate the connector pushing PULL BAR as shown in Fig 7 1 2 there are possibilities to cause PULL BAR deformation or the rotation axis dropping out from the connector Ple...

Страница 7: ...ract the pull tape forcedly toward mating direction It may deform the pull bar or rotation axis may come off from the connector 7 3 7 3 Fig 7 3 7 4 PULL BAR PULL BAR Do not pull the pull bar toward ar...

Страница 8: ...hen you insert only one side in the temporary insert condition maximum slant degree will become 5 By keeping the slant 5 or less deformation of the connector doesn t occur 5 5 5 5 5 slanted condition...

Страница 9: ...ntial C RECE SHELL RECEPTACLE SHELL has an insertion guide as shown in the figure below Please insert connector along this guide As long as inserting along the guide deformation of the connector doesn...

Страница 10: ...tion NG Slanted un mating NG condition OK NG 8 Fig 8 PULL TAPE PULL BAR For the connector with PULL BAR with PULL TAPE PULL TAPE PULL BAR PULL TAPE First pull PULL TAPE to the direction and release th...

Страница 11: ...then turn PULL BAR to direction Un mating method is same as described in Fig 8 Caution Except for part if you pull up the PULL BAR towards direction PULL BAR would have deformation or the connector wo...

Страница 12: ...ing by pulling the horizontal part in parallel to PCB Caution Except for part if you pull up the PULL BAR towards direction PULL BAR would have deformation or the connector would have damage Also if y...

Страница 13: ...connector doesn t occur 5 5 5 5 slanted condition 5 Cautions In case you un mate connector by pulling cable there is possibility to break the cable Please avoid such an un mating method In addition su...

Страница 14: ...edge of pull bar will be cause of short and circuit and disconnection of PCB Layout Therefore please do not apply any load from above Plug PCB PCB CAUTION IN CABLE CONNECTOR HANDLING PULL BAR In case...

Страница 15: ...to the cable attachment part of a plug connector Cable Cable Cable 13 Fig 13 14 Continuous force of the direction shown in black arrow in Fig 14 can damage connectors or cause the coming off from rece...

Страница 16: ...n the receptacle is inserted into the damaged or distorted plug housing and it may cause short circuit Housing PLUG Receptacle Receptacle PLUG PLUG Part No 20490 0 T Plug for electrical inspection Par...

Отзывы: