N700E INSTRUCTION MANUAL
3-47
b50 ~ 55 Load Balance Function
Load Balance is a feature that automatically shares the load level between two independent motors
driving the same load. The Output Frequency of each motor is independently changed by the amount of
torque it is applying. The amount of the increase/decrease is dependent on the amount of torque being
applied.
b52 (Load Balance Gain)
100 %
b53 (Load Balance Start Torque)
t
100%
F(Hz)
(Output Torque
–
Load Balance Start Torque)
100% - Load Balance Start Torque
Control Frequency x
x Load Balance Gain x Load Balance Target Frequency
b50
Load Balance Start Frequency
Range: 0.00 ~ 60.00 Hz in 0.01 Hz
Sets the frequency where the Load Balance Start Frequency feature is enabled.
When running below this frequency the feature is disabled.
b52
Load Balance Gain
Range: 0.00 ~ 50.00 in 0.01
Sets the rate of change when this feature is functioning.
It is based on a percentage of the output torque being applied.
b53
Load Balance Start Torque
Range: 0.0 ~ 100.0 % in 0.1 %
Sets the amount of output torque applied at start when the Load Balance function is
enabled.
b54
Load Balance Ramp Time
Range: 1.0 ~ 100.0 Sec in 0.1 Sec
Sets the ramp rate applied to the output frequency when the Load Balance function is
enabled.
b55
Load Balance Mode
0: Disabled
1: Enabled
Set 0: Disabled
Load balance is disabled
Set 1: Enabled
Load balance works without any feedback