Diagnostics and Troubleshooting
8
XPR300
Instruction Manual
809480
311
How to measure coolant flow
It is necessary for power to be supplied to the cutting system to measure coolant flow.
Use
extreme caution if you do diagnosis or maintenance tasks when the plasma power supply
remains connected to electric power.
1.
Look at the CNC or XPR web interface to identify the coolant flow rate.
2.
Make sure that the coolant flow rate is between 3.79 L/min – 11.36 L/min (1 gal/min –
3 gal/min).
If the flow rate is outside of the correct range, an internal obstruction or
leak can be the cause.
3.
Use an in-line flow meter (128933) to measure internal coolant flow:
a.
Remove the right panel from the plasma power supply.
b.
Find the coolant hose located between the heat-exchanger and coolant filter assembly.
c.
Remove the coolant hose from the coolant filter assembly.
Use a container to catch coolant leaks.
d.
Attach the in-line flow meter (128933) to the hose.
e.
Look at the flow meter measurements. Make sure that the flow is between 3.79 L/min –
11.36 L/min (1 gal/min – 3 gal/min).
Coolant flow measurements from different parts of the cooling system,
can identify the location of an obstruction or restriction. You can use an
in-line flow meter to do this. In-line flow meters (128933) are available
from Hypertherm.
WARNING
The plasma power supply contains dangerous electric voltages that can
cause injury or death.
Even if the cutting system is turned OFF, you can still get a serious
electric shock if the cutting remains connected to an electric power
source
Use extreme caution if you do diagnosis or maintenance tasks when the
plasma power supply remains connected to electricity and the panels on
the plasma power supply are removed.
Содержание XPR300
Страница 1: ...XPR300 Plasma Instruction Manual 809480 Revision 2 English ...
Страница 18: ...Contents 18 809480 Instruction Manual XPR300 ...
Страница 34: ...Specifications 1 34 809480 Instruction Manual XPR300 ...
Страница 66: ...Qualifications and Requirements 2 66 809480 Instruction Manual XPR300 ...
Страница 188: ...Connect for Communication 4 188 809480 Instruction Manual XPR300 ...
Страница 192: ...Coolant Installation 5 192 809480 Instruction Manual XPR300 ...
Страница 230: ...Operation 6 230 809480 Instruction Manual XPR300 ...
Страница 337: ...Parts List 9 XPR300 Instruction Manual 809480 337 ...
Страница 343: ...Parts List 9 XPR300 Instruction Manual 809480 343 ...
Страница 380: ...Wiring Diagrams 10 380 809480 Instruction Manual XPR300 ...
Страница 381: ...381 Overview Sheet 1 of 22 013403 013403 ...
Страница 382: ...382 Plasma power supply 1 Sheet 2 of 22 013403 ...
Страница 383: ...383 Plasma power supply 2 Sheet 3 of 22 013403 ...
Страница 384: ...384 Plasma power supply 3 Sheet 4 of 22 013403 ...
Страница 385: ...385 Plasma power supply 4 Sheet 5 of 22 013403 ...
Страница 386: ...386 Plasma power supply 5 Sheet 6 of 22 013403 ...
Страница 387: ...387 Plasma power supply 6 Sheet 7 of 22 013403 ...
Страница 388: ...388 Plasma power supply 7 Sheet 8 of 22 013403 ...
Страница 389: ...389 Gas connect console 1 Sheet 9 of 22 013403 ...
Страница 390: ...390 Gas connect console 2 Sheet 10 of 22 013403 ...
Страница 391: ...391 Torch connect console Sheet 11 of 22 013403 ...
Страница 392: ...392 Coolant system Sheet 12 of 22 013403 ...
Страница 393: ...393 Gas system 1 Sheet 13 of 22 013403 ...
Страница 394: ...394 Gas system 2 Sheet 14 of 22 013403 ...
Страница 395: ...395 Gas system 3 Sheet 15 of 22 013403 ...
Страница 402: ...402 Wireless subsystem block diagram Sheet 22 of 22 013403 ...