Flow requirements for coolant
The maximum coolant flow rate is 11.36 liters per minute (3.0 US gallons per minute).
The minimum coolant flow rate is 3.79 liters per minute (1 US gallon per minute).
The cutting systems stops automatically if the flow rate reaches this maximum or minimum flow rate.
Automatic, low-flow shut-off protects the coolant pump from damage from low-flow or no-flow
conditions. Automatic, high-flow shut-off protects the torch and leads from damage from a blow-out
event.
For information about how to diagnose and troubleshoot coolant flow issues, see:
Low coolant flow codes (540 – 542)
High coolant flow codes (543 – 544)
Purity requirements for coolant water
Always use water that meets the specifications in
on page 51 when using a custom
coolant mix.
Water that is too pure can also cause problems. Deionized water can cause corrosion in the coolant
system. After deionization, add benzotriazole (128020).
Use water purified by any method (deionization, reverse osmosis, sand filters, water softeners, etc.)
as long as the water purity meets the specifications in the table below. Contact a water specialist for
advice in choosing a water filtration system.
Table 12
– Purity measurement methods for coolant water
Methods to measure water purity
Water purity level
Conductivity
μS/cm
at 25°C (77°F)
Resistivity mΩ∙cm
at 25°C (77°F)
Dissolved solids
or hardness
(ppm of NaCl)
Grains per gallon
(gpg of CaCO
2
)
Pure water
(For reference only. Do
not use.)
0.055
18.3
0
0
Maximum purity
0.5
2
0.206
0.010
Minimum purity
18
0.054
8.5
0.43
Maximum potable water
(For reference only. Do
not use.)
1000
0.001
495
25
Содержание XPR300
Страница 1: ...XPR300 Plasma Instruction Manual 809480 Revision 2 English ...
Страница 18: ...Contents 18 809480 Instruction Manual XPR300 ...
Страница 34: ...Specifications 1 34 809480 Instruction Manual XPR300 ...
Страница 66: ...Qualifications and Requirements 2 66 809480 Instruction Manual XPR300 ...
Страница 188: ...Connect for Communication 4 188 809480 Instruction Manual XPR300 ...
Страница 192: ...Coolant Installation 5 192 809480 Instruction Manual XPR300 ...
Страница 230: ...Operation 6 230 809480 Instruction Manual XPR300 ...
Страница 337: ...Parts List 9 XPR300 Instruction Manual 809480 337 ...
Страница 343: ...Parts List 9 XPR300 Instruction Manual 809480 343 ...
Страница 380: ...Wiring Diagrams 10 380 809480 Instruction Manual XPR300 ...
Страница 381: ...381 Overview Sheet 1 of 22 013403 013403 ...
Страница 382: ...382 Plasma power supply 1 Sheet 2 of 22 013403 ...
Страница 383: ...383 Plasma power supply 2 Sheet 3 of 22 013403 ...
Страница 384: ...384 Plasma power supply 3 Sheet 4 of 22 013403 ...
Страница 385: ...385 Plasma power supply 4 Sheet 5 of 22 013403 ...
Страница 386: ...386 Plasma power supply 5 Sheet 6 of 22 013403 ...
Страница 387: ...387 Plasma power supply 6 Sheet 7 of 22 013403 ...
Страница 388: ...388 Plasma power supply 7 Sheet 8 of 22 013403 ...
Страница 389: ...389 Gas connect console 1 Sheet 9 of 22 013403 ...
Страница 390: ...390 Gas connect console 2 Sheet 10 of 22 013403 ...
Страница 391: ...391 Torch connect console Sheet 11 of 22 013403 ...
Страница 392: ...392 Coolant system Sheet 12 of 22 013403 ...
Страница 393: ...393 Gas system 1 Sheet 13 of 22 013403 ...
Страница 394: ...394 Gas system 2 Sheet 14 of 22 013403 ...
Страница 395: ...395 Gas system 3 Sheet 15 of 22 013403 ...
Страница 402: ...402 Wireless subsystem block diagram Sheet 22 of 22 013403 ...